Literature DB >> 923040

Analysis of left ventricular function from multiple gated acquisition cardiac blood pool imaging. Comparison to contrast angiography.

R D Burow, H W Strauss, R Singleton, M Pond, T Rehn, I K Bailey, L C Griffith, E Nickoloff, B Pitt.   

Abstract

Global ventricular function was evaluated by both multiple gated cardiac blood pool scans (MUGA) and contrast ventriculograms in a group of 17 patients with suspected coronary artery disease. The contrast ventriculograms were analyzed frame by frame to generate a volume versus time curve for each patient, while the tracer data were analyzed by two methods: 1) the standard method, in which the left ventricle is identified on the end-diastolic frame and the background corrected activity under the region of interest obtained from the entire cardiac cycle, and displayed as a time versus activity curve; and 2) by a semi-automatic method in which the computer applies a threshold detection program to define the ventricular borders, and activity in the chamber at each point in the cardiac cycle is defined after background correction. The tracer data in each patient were analyzed independently by four observers. The tracer data correlated with the contrast data on a point by point basis r = 0.87 for the standard method, and 0.93 for the semi-automatic technique. An F test of variance revealed the semi-automatic method superior to the standard approach (P less than 0.05).

Entities:  

Mesh:

Year:  1977        PMID: 923040     DOI: 10.1161/01.cir.56.6.1024

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  34 in total

1.  Blood pool ventriculography with a new technetium-labelled complex (99mTc-DEPIC): a clinical evaluation.

Authors:  G Brigden; G Zanelli; A Lahiri; E Raftery
Journal:  Eur J Nucl Med       Date:  1990

2.  Equilibrium gated radionuclide angiocardiography: Its invention, rise, and decline and … comeback?

Authors:  Frans J Th Wackers
Journal:  J Nucl Cardiol       Date:  2016-01-27       Impact factor: 5.952

3.  Factor analysis of multigated cardiac blood pool scintigram for the measurement of left ventricular ejection fraction.

Authors:  N Honda; K Machida; T Mamiya; T Takahashi; T Takishima; T Kamano; N Hasegawa; M Hashimoto; K Ohno; M Hosoba
Journal:  Ann Nucl Med       Date:  1989-07       Impact factor: 2.668

Review 4.  Cardiomyopathy associated with cancer therapy.

Authors:  Anthony F Yu; Richard M Steingart; Valentin Fuster
Journal:  J Card Fail       Date:  2014-08-21       Impact factor: 5.712

5.  Regional observer performance variation in the evaluation of gated cardiac blood pool studies.

Authors:  S A Jackson; R Nickerson; R H Martin; S Iles; D Barnes
Journal:  Eur J Nucl Med       Date:  1992

6.  Digitizing and signal averaging of left ventricular pressure signals using a dedicated radionuclide imaging system.

Authors:  C P Herbst; K J Dormer; D J Brackett; M F Wilson; B Barkan; R D Burow
Journal:  Eur J Nucl Med       Date:  1987

7.  A comparison of two radionuclide ejection-fraction techniques with contrast angiography in ischemic heart disease and valvular heart disease.

Authors:  I M Hassan; M M Mohammed; M Badruddosa; A R Mahmood; M E Sayed; M Simo; H M Abdel-Dayem; A M Yousef
Journal:  Eur J Nucl Med       Date:  1986

8.  Left ventricular function during graded exercise in patients with coronary artery disease and in control subjects.

Authors:  L J Melendez; D E Manyari; A A Driedger; T D Cradduck; A C MacDonald
Journal:  Can Med Assoc J       Date:  1981-03-01       Impact factor: 8.262

9.  Effect of oral propranolol on rest and exercise left ventricular ejection fraction, volumes, and segmental wall motion in patients with angina pectoris. Assessment with equilibrium gated blood pool imaging.

Authors:  G J Dehmer; M Falkoff; S E Lewis; L D Hillis; R W Parkey; J T Willerson
Journal:  Br Heart J       Date:  1981-06

10.  Assessment of cardiac and renal function in children immediately after open-heart surgery: the significance of a reduced radionuclide ejection fraction (postoperative ejection fraction).

Authors:  W Covitz; C Eubig; H V Moore; A T Truman; B B Sellers; R Shelnutt; B Hadden
Journal:  Pediatr Cardiol       Date:  1984 Jul-Sep       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.