Literature DB >> 2641452

Factor analysis of multigated cardiac blood pool scintigram for the measurement of left ventricular ejection fraction.

N Honda1, K Machida, T Mamiya, T Takahashi, T Takishima, T Kamano, N Hasegawa, M Hashimoto, K Ohno, M Hosoba.   

Abstract

Left ventricular ejection fraction (EF) was measured by factor analysis (FA) of multigated cardiac blood pool scintigram in 38 consecutive patients, and compared with that measured by the variable ROI method (EFVROI) with automated left ventricular contour detection. FA was automatically performed without operator intervention with a success rate of 100%. The correlation of EF with EFVROI was significant in the group of 22 patients with normal wall motion (r = 0.65, p less than 0.001), and the entire group of patients (r = 0.70, p less than 0.001), but not significant (p = 0.19) in the group of 16 patients with abnormal wall motion. In conclusion, left ventricular ejection fraction can be estimated by factor analysis of MUGA in patients with normal wall motion.

Entities:  

Mesh:

Year:  1989        PMID: 2641452     DOI: 10.1007/bf03164589

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  18 in total

1.  Use of factor analysis in the evaluation of left to right cardiac shunts.

Authors:  J Villanueva-Meyer; L Philippe; S Cordero; C S Marcus; I Mena
Journal:  J Nucl Med       Date:  1986-09       Impact factor: 10.057

2.  Clinical validation of fully-automated contour detection for gated radionuclide ventriculography with a slant-hole collimator.

Authors:  M Hosoba; H Wani; M Hiroe; K Kusakabe
Journal:  Eur J Nucl Med       Date:  1986

3.  Reproducibility of ejection fraction and ventricular volume by gated radionuclide angiography after myocardial infarction.

Authors:  R Slutsky; J Karliner; A Battler; M Pfisterer; S Swanson; W Ashburn
Journal:  Radiology       Date:  1979-07       Impact factor: 11.105

4.  Factor analysis in left ventricular first-pass radionuclide angiography: value of the ventricular factor to measure ejection fraction.

Authors:  J C Maublant; I Mena; L G Hanelin
Journal:  Int J Card Imaging       Date:  1985

5.  A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterization.

Authors:  H W Strauss; B L Zaret; P J Hurley; T K Natarajan; B Pitt
Journal:  Am J Cardiol       Date:  1971-11       Impact factor: 2.778

6.  Ejection fraction by count rate from gated images.

Authors:  M V Green; W R Brody; M A Douglas; J S Borer; H G Ostrow; B R Line; S L Bacharach; G S Johnston
Journal:  J Nucl Med       Date:  1978-08       Impact factor: 10.057

7.  The radionuclide ejection fraction: a comparison of three radionuclide techniques with contrast angiography.

Authors:  E D Folland; G W Hamilton; S M Larson; J W Kennedy; D L Williams; J L Ritchie
Journal:  J Nucl Med       Date:  1977-12       Impact factor: 10.057

8.  Analysis of left ventricular function from multiple gated acquisition cardiac blood pool imaging. Comparison to contrast angiography.

Authors:  R D Burow; H W Strauss; R Singleton; M Pond; T Rehn; I K Bailey; L C Griffith; E Nickoloff; B Pitt
Journal:  Circulation       Date:  1977-12       Impact factor: 29.690

9.  Reproducibility of ejection-fraction determinations by equilibrium radionuclide angiography in response to supine bicycle exercise: concise communication.

Authors:  M E Pfisterer; A Battler; S M Swanson; R Slutsky; V Froelicher; W L Ashburn
Journal:  J Nucl Med       Date:  1979-06       Impact factor: 10.057

10.  Validity of different gated equilibrium blood pool methods for determination of left ventricular ejection fraction.

Authors:  K R Karsch; H Schicha; P Rentrop; H Kreuzer; D Emrich
Journal:  Eur J Nucl Med       Date:  1980-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.