The cutting efficiency of endodontic instruments was measured using an original experimental technique that incorporates new concepts to simulate clinical conditions. Five designs of #ISO 030 endodontic instruments, K-reamer (Maillefer), Flexofile (Maillefer), Helifile (Micro-mega), K-flex (Kerr), and Unifile (De Trey), were chosen and their cutting efficiency assessed at their full working length of 16 mm on two Plexiglas parallelepipeds tilted to follow the 2% conicity of the instruments. For each instrument, four series of 25 cuts were carried out and each cut made on a new flat, smooth Plexiglas surface with an even hardness of 33 VHN. Instruments were tested under a simulated clinical condition of a quarter clockwise turn ROTARY MOTION followed by a PULL ACTION at 16 mm/s rate, with a fixed load on the instrument of 325 g. Water irrigation at a rate of 85 ml/s was supplied before each procedure. Cutting efficiency was evaluated in terms of mass of Plexiglas cut (using a Mettler analytic balance with accuracy of 3 x 10(-5) g) per unit of energy used by the instrument, i.e. mg/J. Unifile was found to have the best cutting efficiency of 0.80 +/- 0.01 (Mean +/- SD) and lowest cutting efficiency loss followed by Flexofile 0.70 +/- 0.03 then Helifile 0.36 +/- 0.01 then K-flex 0.51 +/- 0.07. K-reamer was found to have the lowest cutting efficiency of 0.16 +/- 0.05.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9220749     DOI: 10.1016/S0099-2399(96)80058-6

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  6 in total

1.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

2.  Effect of cryogenic treatment on nickel-titanium endodontic instruments.

Authors:  J W Kim; J A Griggs; J D Regan; R A Ellis; Z Cai
Journal:  Int Endod J       Date:  2005-06       Impact factor: 5.264

3.  Cutting efficiency of instruments with different movements: a comparative study.

Authors:  Luigi Tocci; Gianluca Plotino; Dina Al-Sudani; Alessio Giansiracusa Rubini; Gianpaolo Sannino; Lucila Piasecki; Ermanno Putortì; Luca Testarelli; Gianluca Gambarini
Journal:  J Oral Maxillofac Res       Date:  2015-03-30

4.  A new device to test cutting efficiency of mechanical endodontic instruments.

Authors:  Alessio Giansiracusa Rubini; Gianluca Plotino; Dina Al-Sudani; Nicola M Grande; Gianpaolo Sonnino; Ermanno Putorti; Elisabetta Cotti; Luca Testarelli; Gianluca Gambarini
Journal:  Med Sci Monit       Date:  2014-03-06

5.  Influence of heat treatment on cyclic fatigue and cutting efficiency of ProTaper Universal F2 instruments.

Authors:  Chih-Wen Chi; Eddie Hsiang-Hua Lai; Chao-Yuan Liu; Chun-Pin Lin; Chow-Shing Shin
Journal:  J Dent Sci       Date:  2016-08-10       Impact factor: 2.080

6.  Influence of kinematics and incidence angles on the cutting efficiency of two single-file nickel-titanium rotary instruments.

Authors:  Eugenio Pedullà; Giusy Rita Maria La Rosa; Giuseppe Romano; Giuseppe Leanza; Silvia Rapisarda; Gaetano Isola; Sebastiano Ferlito; Prasanna Neelakantan; Luigi Generali
Journal:  Aust Endod J       Date:  2021-07-13       Impact factor: 1.719

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.