Literature DB >> 9220220

Outcomes and costs of positron emission tomography: comparison of intravenous adenosine and intravenous dipyridamole.

M J Holmberg1, S M Mohiuddin, D E Hilleman, B D Lucas, E C Wadibia.   

Abstract

The objective of this study was to compare the cost of intravenous adenosine and intravenous dipyridamole in positron emission tomography (PET) in patients with coronary artery disease. A retrospective, open-label, case-control, cost-effectiveness analysis was performed in the out-patient nuclear medicine department of a university hospital. Thirty-six patients underwent dipyridamole PET, and 72 matched patients underwent adenosine PET. A cost-effectiveness analysis was conducted using a direct cost accounting approach to estimate institutional costs. Key costs evaluated included acquisition cost, administration cost, monitoring cost, cost of management of side effects, and cost of follow-up care. The total cost of adenosine PET and dipyridamole PET was divided by their respective predictive accuracies to provide a total cost adjusted for efficacy. Adenosine increased heart rate and lowered systolic blood pressure to a significantly greater extent than dipyridamole. The number of patients experiencing adverse drug reactions was significantly greater for adenosine (82%) than for dipyridamole (67%), but the frequency of prolonged (> 5 minutes) and late-onset side effects was significantly greater for dipyridamole than for adenosine. The frequency of side effects requiring medical intervention was also significantly greater for dipyridamole (53%) than for adenosine (6%). Although adenosine had a significantly greater acquisition cost than dipyridamole, costs of monitoring, management of side effects, and follow-up care were significantly less for adenosine than for dipyridamole. As a result, the total cost of using dipyridamole is significantly greater ($928.00 per patient) than the total cost of using adenosine ($672.00 per patient). Based on these results, adenosine may be the drug of choice for pharmacologic vasodilation for PET.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9220220     DOI: 10.1016/s0149-2918(97)80141-5

Source DB:  PubMed          Journal:  Clin Ther        ISSN: 0149-2918            Impact factor:   3.393


  1 in total

1.  Investigation of emission-transmission misalignment artifacts on rubidium-82 cardiac PET with adenosine pharmacologic stress.

Authors:  David M Schuster; Raghuveer K Halkar; Fabio P Esteves; Ernest V Garcia; C David Cooke; Mushabbar A Syed; F DuBois Bowman; John R Votaw
Journal:  Mol Imaging Biol       Date:  2008-05-03       Impact factor: 3.488

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.