Literature DB >> 9212711

A MALDI probe for mass spectrometers.

J D Lennon1, G L Glish.   

Abstract

A new MALDI probe has been designed that uses transmission geometry. This geometry allows the probe to be fashioned after typical EI/CI solid probes which enables it to be introduced into spatially constrained ion source regions such as encountered in quadrupole ion trap mass spectrometers. In the probe design demonstrated here, light from a fiber optic irradiates the backside of a sample through a small piece of quartz on which the sample has been directly deposited. The performance characteristics exhibited by utilizing this probe for MALDI on a quadrupole ion trap mass spectrometer are similar to those which can be obtained through the traditional methods of implementing MALDI. Spectra have been obtained from 50 fmol of total loading of bombesin, MS/MS has been performed on 5 pmol of des-Arg9-bradykinin, and the analyte ion signal is shown to last for over 2500 laser shots for 2 pmol of bombesin. Optical micrographs showing the crystal distribution of a sample containing 2 pmol of bombesin have been obtained as a function of the number of laser shots for a single sample loading. Although this probe was designed for use with the quadrupole ion trap, it can be adapted for use with all types of mass spectrometers. Thus, with only one laser, one fiber optic, and this probe, MALDI can be performed on multiple instruments in a lab.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9212711     DOI: 10.1021/ac961291q

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Laser desorption in transmission geometry inside a Fourier-transform ion cyclotron resonance mass spectrometer.

Authors:  J Pérez; C J Petzold; M A Watkins; W E Vaughn; H I Kenttämaa
Journal:  J Am Soc Mass Spectrom       Date:  1999-11       Impact factor: 3.109

2.  Laserspray ionization using an atmospheric solids analysis probe for sample introduction.

Authors:  Frank Zydel; Sarah Trimpin; Charles N McEwen
Journal:  J Am Soc Mass Spectrom       Date:  2010-07-22       Impact factor: 3.109

3.  Laser-induced acoustic desorption coupled with a linear quadrupole ion trap mass spectrometer.

Authors:  Steven C Habicht; Lucas M Amundson; Penggao Duan; Nelson R Vinueza; Hilkka I Kenttämaa
Journal:  Anal Chem       Date:  2010-01-15       Impact factor: 6.986

4.  Analysis of biomolecules by atmospheric pressure visible-wavelength MALDI-ion trap-MS in transmission geometry.

Authors:  Raymond E West; Eric W Findsen; Dragan Isailovic
Journal:  J Am Soc Mass Spectrom       Date:  2013-07-27       Impact factor: 3.109

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.