Literature DB >> 20000769

Laser-induced acoustic desorption coupled with a linear quadrupole ion trap mass spectrometer.

Steven C Habicht1, Lucas M Amundson, Penggao Duan, Nelson R Vinueza, Hilkka I Kenttämaa.   

Abstract

In recent years, laser-induced acoustic desorption (LIAD) coupled with a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer has been demonstrated to provide a valuable technique for the analysis of a wide variety of nonvolatile, thermally labile compounds, including analytes that could not previously be analyzed by mass spectrometry. Although FT-ICR instruments are very powerful, they are also large and expensive and, hence, mainly used as research instruments. In contrast, linear quadrupole ion trap (LQIT) mass spectrometers are common due to several qualities that make these instruments attractive for both academic and industrial settings, such as high sensitivity, large dynamic range, and experimental versatility. Further, the relatively small size of the instruments, comparatively low cost, and the lack of a magnetic field provide some distinct advantages over FT-ICR instruments. Hence, we have coupled the LIAD technique with a commercial LQIT, the Thermo Fischer Scientific LTQ mass spectrometer. The LQIT was modified for a LIAD probe by outfitting the removable back plate of the instrument with a 6 in. ConFlat flange (CFF) port, gate valve, and sample lock. Reagent ions were created using the LQIT's atmospheric pressure ionization source and trapped in the mass analyzer for up to 10 s to allow chemical ionization reactions with the neutral molecules desorbed via LIAD. These initial experiments focused on demonstrating the feasibility of performing LIAD in the LQIT. Hence, the results are compared to those obtained using an FT-ICR mass spectrometer. Despite the lower efficiency in the transfer of desorbed neutral molecules into the ion trap, and the smaller maximum number of available laser pulses, the intrinsically higher sensitivity of the LQIT resulted in a higher sensitivity relative to the FT-ICR.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20000769      PMCID: PMC2806935          DOI: 10.1021/ac901943k

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  28 in total

1.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

2.  Characterization of laser-induced acoustic desorption coupled with a Fourier transform ion cyclotron resonance mass spectrometer.

Authors:  Ryan C Shea; Christopher J Petzold; J Larry Campbell; Sen Li; David J Aaserud; Hilkka I Kenttämaa
Journal:  Anal Chem       Date:  2006-09-01       Impact factor: 6.986

3.  Molar mass and molar mass distribution of polystyrene particle size standards.

Authors:  Wen-Ping Peng; Yi-Chang Yang; Chung-Wei Lin; Huan-Cheng Chang
Journal:  Anal Chem       Date:  2005-11-01       Impact factor: 6.986

4.  Experimental investigations of the internal energy of molecules evaporated via laser-induced acoustic desorption into a Fourier transform ion cyclotron resonance mass spectrometer.

Authors:  Ryan C Shea; Christopher J Petzold; Ji-Ang Liu; Hilkka I Kenttämaa
Journal:  Anal Chem       Date:  2007-01-31       Impact factor: 6.986

5.  A MALDI probe for mass spectrometers.

Authors:  J D Lennon; G L Glish
Journal:  Anal Chem       Date:  1997-07-01       Impact factor: 6.986

6.  Reactions of charged phenyl radicals with aliphatic amino acids in the gas phase.

Authors:  Yiqun Huang; Leo Guler; Jenny Heidbrink; Hilkka Kenttämaa
Journal:  J Am Chem Soc       Date:  2005-03-23       Impact factor: 15.419

7.  Using laser-induced acoustic desorption/electrospray ionization mass spectrometry to characterize small organic and large biological compounds in the solid state and in solution under ambient conditions.

Authors:  Sy-Chyi Cheng; Tain-Lu Cheng; Hui-Chiu Chang; Jentaie Shiea
Journal:  Anal Chem       Date:  2009-02-01       Impact factor: 6.986

8.  Analysis of base oil fractions by ClMn(H2O)+ chemical ionization combined with laser-induced acoustic desorption/fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Penggao Duan; Kuangnan Qian; Steven C Habicht; David S Pinkston; Mingkun Fu; Hilkka I Kenttämaa
Journal:  Anal Chem       Date:  2008-02-22       Impact factor: 6.986

9.  Gas-phase reactivity of aromatic sigma,sigma-biradicals toward dinucleoside phosphates.

Authors:  Linan Yang; John J Nash; Michael J Yurkovich; Zhicheng Jin; Nelson R Vinueza; Hilkka I Kenttämaa
Journal:  Org Lett       Date:  2008-04-23       Impact factor: 6.005

10.  Trapping of a tert-adamantyl peroxyl radical in the gas phase.

Authors:  David G Harman; Stephen J Blanksby
Journal:  Chem Commun (Camb)       Date:  2006-01-06       Impact factor: 6.222

View more
  2 in total

1.  Laser-induced acoustic desorption/atmospheric pressure chemical ionization mass spectrometry.

Authors:  Jinshan Gao; David J Borton; Benjamin C Owen; Zhicheng Jin; Matt Hurt; Lucas M Amundson; Jeremy T Madden; Kuangnan Qian; Hilkka I Kenttämaa
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-15       Impact factor: 3.109

2.  A distonic radical-ion for detection of traces of adventitious molecular oxygen (O2) in collision gases used in tandem mass spectrometers.

Authors:  Freneil B Jariwala; John A Hibbs; Carl S Weisbecker; John Ressler; Rahul L Khade; Yong Zhang; Athula B Attygalle
Journal:  J Am Soc Mass Spectrom       Date:  2014-07-08       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.