Literature DB >> 9211387

Density compensation functions for spiral MRI.

R D Hoge1, R K Kwan, G B Pike.   

Abstract

In interleaved spiral MRI, an object's Fourier transform is sampled along a set of curved trajectories in the spatial frequency domain (k-space). An image of the object is then reconstructed, usually by interpolating the sampled Fourier data onto a Cartesian grid and applying the fast Fourier transform (FFT) algorithm. To obtain accurate results, it is necessary to account for the nonuniform density with which k-space is sampled. An analytic density compensation function (DCF) for spiral MRI, based on the Jacobian determinant for the transformation between Cartesian coordinates and the spiral sampling parameters of time and interleaf rotation angle, is derived in this paper, and the reconstruction accuracy achieved using this function is compared with that obtained using several previously published expressions. Various nonideal conditions, including intersecting trajectories, are considered. The new DCF eliminated intensity cupping that was encountered in images reconstructed with other functions, and significantly reduced the level of artifact observed when unevenly spaced sampling trajectories, such as those achieved with trapezoidal gradient waveforms, were employed. Modified forms of this function were found to provide similar improvements when intersecting trajectories made the spiral-Cartesian transformation noninvertible, and when the shape of the spiral trajectory varied between interleaves.

Entities:  

Mesh:

Year:  1997        PMID: 9211387     DOI: 10.1002/mrm.1910380117

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  2D-RF-pulse-encoded curved-slice imaging.

Authors:  Peter Börnert
Journal:  MAGMA       Date:  2003-07-08       Impact factor: 2.310

2.  On spatially selective RF excitation and its analogy with spiral MR image acquisition.

Authors:  P Börnert; B Aldefeld
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

3.  Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI.

Authors:  Ali Gholipour; Onur Afacan; Iman Aganj; Benoit Scherrer; Sanjay P Prabhu; Mustafa Sahin; Simon K Warfield
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

4.  Improvements in spiral MR imaging.

Authors:  P Börnert; H Schomberg; B Aldefeld; J Groen
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

5.  Deconvolution-interpolation gridding (DING): accurate reconstruction for arbitrary k-space trajectories.

Authors:  Refaat E Gabr; Pelin Aksit; Paul A Bottomley; Abou-Bakr M Youssef; Yasser M Kadah
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

6.  Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses.

Authors:  Dimitris Mitsouras; Robert V Mulkern; Frank J Rybicki
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

7.  Multispectral imaging with three-dimensional rosette trajectories.

Authors:  Elizabeth K Bucholz; Jiayu Song; G Allan Johnson; Ileana Hancu
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

8.  Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.

Authors:  Weitian Chen; Christopher T Sica; Craig H Meyer
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

9.  High efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE).

Authors:  Lawrence R Frank; Youngkyoo Jung; Souheil Inati; J Michael Tyszka; Eric C Wong
Journal:  Neuroimage       Date:  2009-09-22       Impact factor: 6.556

Review 10.  Magnetic Resonance Sequences and Rapid Acquisition for MR-Guided Interventions.

Authors:  Adrienne E Campbell-Washburn; Anthony Z Faranesh; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.