Literature DB >> 9211139

Appositional angle closure in eyes with narrow angles: an ultrasound biomicroscopic study.

T Sakuma1, A Sawada, T Yamamoto, Y Kitazawa.   

Abstract

PURPOSE: To demonstrate appositional angle closure using ultrasound biomicroscopy under dark room conditions, to investigate patterns of appositional closure, and to correlate those patterns with the angle topology in eyes with narrow angles.
METHODS: Forty-six eyes that met the study criteria, from 46 individuals, were examined by ultrasound biomicroscopy under dark room and illuminated conditions.
RESULTS: In 40 of the 46 eyes (87.0%), appositional closure was identified by ultrasound biomicroscopy. Two distinct patterns of angle closure were seen: type B, in which closure starts from the bottom of the angle, and type S, in which closure starts in the vicinity of Schwalbe's line. In type B, the iris root was located closure to the chamber angle than in type S.
CONCLUSIONS: Ultrasound biomicroscopy performed under dark room conditions is a useful technique for identifying appositional angle closure in eyes with narrow angles. The topology of the iris root is related to the pattern of the appositional angle closure.

Mesh:

Year:  1997        PMID: 9211139

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  10 in total

1.  [OCT-goniometry before and after iridotomy in angle-closure glaucoma].

Authors:  A Karandish; C Wirbelauer; H Häberle; D T Pham
Journal:  Ophthalmologe       Date:  2006-01       Impact factor: 1.059

2.  Qualitative assessment of ultrasound biomicroscopic images using standard photographs: the liwan eye study.

Authors:  Yuzhen Jiang; Mingguang He; Wenyong Huang; Qunxiao Huang; Jian Zhang; Paul J Foster
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-10-15       Impact factor: 4.799

3.  Appositional closure identified by ultrasound biomicroscopy in population-based primary angle-closure glaucoma suspects: the Liwan eye study.

Authors:  Xiangbin Kong; Paul J Foster; Qunxiao Huang; Yingfeng Zheng; Wenyong Huang; Xiaoyu Cai; Mingguang He
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-07       Impact factor: 4.799

4.  Comparison of iris insertion classification among american caucasian and ethnic Chinese using ultrasound biomicroscopy.

Authors:  Ye Elaine Wang; Yingjie Li; Dandan Wang; Mingguang He; Lingling Wu; Shan C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-06-03       Impact factor: 4.799

5.  Light-dark changes in iris thickness and anterior chamber angle width in eyes with occludable angles.

Authors:  Fumitaka Hirose; Masayuki Hata; Shin-ichiro Ito; Takaaki Matsuki; Yasuo Kurimoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-21       Impact factor: 3.117

6.  YAG laser iridotomy treatment for primary angle closure in east Asian eyes.

Authors:  W P Nolan; P J Foster; J G Devereux; D Uranchimeg; G J Johnson; J Baasanhu
Journal:  Br J Ophthalmol       Date:  2000-11       Impact factor: 4.638

7.  Changes in anterior chamber configuration after cataract surgery as measured by anterior segment optical coherence tomography.

Authors:  Martha Kim; Ki Ho Park; Tae-Woo Kim; Dong Myung Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11

8.  Relationship between relative lens position and appositional closure in eyes with narrow angles.

Authors:  Yasumasa Otori; Yuki Tomita; Ayumi Hamamoto; Kanae Fukui; Shinichi Usui; Misako Tatebayashi
Journal:  Jpn J Ophthalmol       Date:  2011-03-13       Impact factor: 2.447

9.  Peripheral anterior synechiae and ultrasound biomicroscopic parameters in angle-closure glaucoma suspects.

Authors:  Chungkwon Yoo; Jong Hyun Oh; Yong Yeon Kim; Hai Ryun Jung
Journal:  Korean J Ophthalmol       Date:  2007-06

10.  Differences between fellow eyes of acute and chronic primary angle closure (glaucoma): An ultrasound biomicroscopy quantitative study.

Authors:  Mengwei Li; Yuhong Chen; Xiaoxiao Chen; Wenqing Zhu; Xueli Chen; Xiaolei Wang; Yuan Fang; Xiangmei Kong; Yi Dai; Junyi Chen; Xinghuai Sun
Journal:  PLoS One       Date:  2018-02-15       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.