Literature DB >> 9207774

In vitro wear of composite with varied cure, filler level, and filler treatment.

J R Condon1, J L Ferracane.   

Abstract

For the clinical wear of composite filing materials to be reduced, compositional factors such as degree of cure, filler level, and silanation level should be optimized. An oral-wear-stimulating machine was used to explore the effects of these factors on abrasion and attrition wear as well as on opposing enamel wear. The composites were made from Sr glass (1-2 micron avg) and a 50/50 Bis-GMA/TEGDMA resin. Series I (A-D, E) were light-cured (Triad II) for 9, 12, 25, and 40 sec/side to produce degree of cure (DC) as measured by FTIR of 56, 60, 61, and 63%, respectively. E received an additional heat cure (120 degrees C for 10 min) to reach a DC of 66%. Series II (D, F-I) were filled to 62, 53, 48, 37, and 28 vol%, respectively. In series III (D, J-M), the portion of fillers treated with a silane coupler (MPS) was 100, 80, 60, 40, and 20%, respectively. Samples were cycled 50,000 times against an enamel antagonist in a poppy seed/PMMA slurry in the oral wear simulator to produce abrasion (load = 20 N) and attrition (load = 70 N) simultaneously. Wear depth (micron: n = 5) was measured by profilometry. Results for each series were analysed by ANOVA/Turkey's (p < or = 0.05). The wear depths did reflect cure values, though only the abrasion difference for E < A was significant. Greater wear was correlated with lower filler levels (r2 = 0.88; p < 0.05), significantly increasing below 48 vol% (G). Wear increased linearly as the percent of silane-treated fillers was reduced (r2 = 0.99; p < 0.05). Abrasion and attrition did not differ significantly for any composite. Wear of the opposing enamel was largely unchanged by these factors. Compositional factors including degree of cure, filler level, and silanation directly affected the wear resistance of dental composites evaluated in an oral wear simulator.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9207774     DOI: 10.1177/00220345970760071101

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  21 in total

1.  Effect of thermal cycling on whisker-reinforced dental resin composites.

Authors:  Hockin H K Xu; Frederick C Eichmiller; Douglas T Smith; Gary E Schumacher; Anthony A Giuseppetti; Joseph M Antonucci
Journal:  J Mater Sci Mater Med       Date:  2002-09       Impact factor: 3.896

2.  Comparative study of the wear behavior of composites for posterior restorations.

Authors:  Cecilia P Turssi; Juliana J Faraoni-Romano; Márcio de Menezes; Mônica C Serra
Journal:  J Mater Sci Mater Med       Date:  2007-01       Impact factor: 3.896

3.  An in vitro investigation of wear resistance and hardness of composite resins.

Authors:  Liqun Cao; Xinyi Zhao; Xu Gong; Shouliang Zhao
Journal:  Int J Clin Exp Med       Date:  2013-06-26

4.  Two-body wear of dental porcelain and substructure oxide ceramics.

Authors:  Martin Rosentritt; Verena Preis; Michael Behr; Sebastian Hahnel; Gerhard Handel; Carola Kolbeck
Journal:  Clin Oral Investig       Date:  2011-07-08       Impact factor: 3.573

5.  Are resin composites suitable replacements for amalgam? A study of two-body wear.

Authors:  Dimitra Lazaridou; Renan Belli; Anselm Petschelt; Ulrich Lohbauer
Journal:  Clin Oral Investig       Date:  2014-12-10       Impact factor: 3.573

6.  Nanohybrid and microfilled hybrid versus conventional hybrid composite restorations: 5-year clinical wear performance.

Authors:  Senthamaraiselvi Palaniappan; Liesbeth Elsen; Inge Lijnen; Marleen Peumans; Bart Van Meerbeek; Paul Lambrechts
Journal:  Clin Oral Investig       Date:  2011-01-11       Impact factor: 3.573

7.  Influence of bioactive particles on the chemical-mechanical properties of experimental enamel resin infiltrants.

Authors:  Ravana Angelini Sfalcin; Américo Bortolazzo Correr; Lucas Rafael Morbidelli; Tatiany Gabrielle Freire Araújo; Victor Pinheiro Feitosa; Lourenço Correr-Sobrinho; Timothy Frederick Watson; Salvatore Sauro
Journal:  Clin Oral Investig       Date:  2016-11-12       Impact factor: 3.573

8.  Modification of filler surface treatment of composite resins using alternative silanes and functional nanogels.

Authors:  Bruna Marin Fronza; Steven Lewis; Parag K Shah; Matthew D Barros; Marcelo Giannini; Jeffrey W Stansbury
Journal:  Dent Mater       Date:  2019-04-16       Impact factor: 5.304

Review 9.  Degradation, fatigue, and failure of resin dental composite materials.

Authors:  J L Drummond
Journal:  J Dent Res       Date:  2008-08       Impact factor: 6.116

10.  Effect of Accelerated Aging on Some Mechanical Properties and Wear of Different Commercial Dental Resin Composites.

Authors:  Jonne Oja; Lippo Lassila; Pekka K Vallittu; Sufyan Garoushi
Journal:  Materials (Basel)       Date:  2021-05-23       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.