Fracture embolization of a Duromedics mitral prosthesis.

F J Baumgartner1, A I Munro, W R Jamieson.   

Abstract

The Duromedics bileaflet pyrolitic carbon mechanical prosthesis was introduced by Hemex in 1982 and subsequently acquired by Baxter. This communication documents a case of sudden leaflet fracture of a Duromedics mitral valve 48 months after implantation, which was managed successfully by replacement with a St. Jude Medical mechanical prosthesis. The patient presented in acute distress with paroxysmal atrial tachycardia and pulmonary edema. Transesophageal echocardiography was used to diagnose the leaflet fracture. The fracture had occurred transversely, with the fragments embolizing bilaterally to the iliofemoral arteries. These were removed at a subsequent operation. Cases of such fractures of the Duromedics prosthesis have been reported, with cavitation damage being the postulated mechanism.

Entities:  

Mesh:

Year:  1997        PMID: 9205987      PMCID: PMC325416     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  10 in total

1.  Cavitation potential of mechanical heart valve prostheses.

Authors:  T Graf; H Fischer; H Reul; G Rau
Journal:  Int J Artif Organs       Date:  1991-03       Impact factor: 1.595

2.  Embolization of disc occluder of a Wada-Cutter mitral prosthesis with survival.

Authors:  A K Roberts; C J Lambert; B F Mitchel
Journal:  Ann Thorac Surg       Date:  1976-04       Impact factor: 4.330

3.  Leaflet escape of a mitral Duromedics prosthesis. Case report.

Authors:  F E Deuvaert; J Devriendt; J Massaut; G Van Nooten; J De Paepe; G Primo
Journal:  Acta Chir Belg       Date:  1989 Jan-Feb       Impact factor: 1.090

4.  Leaflet fracture in Edwards-Duromedics bileaflet valves.

Authors:  W Klepetko; A Moritz; J Mlczoch; H Schurawitzki; E Domanig; E Wolner
Journal:  J Thorac Cardiovasc Surg       Date:  1989-01       Impact factor: 5.209

5.  Cavitation threshold ranking and erosion characteristics of bileaflet heart valve prostheses.

Authors:  G Richard; A Beavan; P Strzepa
Journal:  J Heart Valve Dis       Date:  1994-04

6.  Spontaneous embolization of a St. Jude prosthetic mitral valve leaflet.

Authors:  J A Odell; J Durandt; D M Shama; S Vythilingum
Journal:  Ann Thorac Surg       Date:  1985-06       Impact factor: 4.330

7.  Strut fracture and disc embolization in Björk-Shiley mitral valve prostheses: diagnosis and management.

Authors:  P K Davis; J L Myers; J L Pennock; B L Thiele
Journal:  Ann Thorac Surg       Date:  1985-07       Impact factor: 4.330

Review 8.  Fracture of the Duromedics mitral valve housing with leaflet escape.

Authors:  W R Dimitri; B T Williams
Journal:  J Cardiovasc Surg (Torino)       Date:  1990 Jan-Feb       Impact factor: 1.888

9.  A 8-year follow-up of the Edwards-Duromedics bileaflet prosthesis.

Authors:  E Baudet; X Roques; J McBride; F Panès; J P Grimaud
Journal:  J Cardiovasc Surg (Torino)       Date:  1995-10       Impact factor: 1.888

10.  Four year follow-up of the Duromedics Edwards bileaflet valve prostheses.

Authors:  A Moritz; W Klepetko; G Khünl-Brady; W Schreiner; I Pabinger; H Bailer; I Lang; E Wolner
Journal:  J Cardiovasc Surg (Torino)       Date:  1990 May-Jun       Impact factor: 1.888

  10 in total
  2 in total

1.  Cohort survey of heart valve replacement patients: does the valve card scheme have room for improvement?

Authors:  M B Edwards; K M Taylor
Journal:  BMJ       Date:  2001-08-25

2.  Spontaneous leaflet fracture resulting in embolization from mechanical valve prostheses.

Authors:  Gijs G J van Steenbergen; Queeny H Y Tsang; Stefan M van der Heide; Michel W A Verkroost; Wilson W L Li; Wim J Morshuis
Journal:  J Card Surg       Date:  2018-12-30       Impact factor: 1.620

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.