Literature DB >> 9202352

Clinical predictors of transvenous biphasic defibrillation thresholds.

M R Gold1, K Khalighi, N G Kavesh, B Daly, R W Peters, S R Shorofsky.   

Abstract

Transvenous lead systems have become routine for defibrillator placement. However, previous studies of clinical predictors of an adequate nonthoracotomy defibrillation threshold (DFT) evaluated monophasic waveforms or more complex lead systems, including subcutaneous patches. Accordingly, this study is a prospective evaluation of the predictors of an adequate biphasic DFT in 114 consecutive patients undergoing cardioverter-defibrillator implantation with a single transvenous lead. For each subject, 38 parameters were assessed, including standard demographic, electrocardiographic, echocardiographic, and radiographic measurements. An adequate DFT (< or =20 J) was achieved in 92% of patients. Multivariable analysis revealed 2 independent factors predictive of a high threshold: echocardiographic measurements of left ventricular dilation (odds ratio = 0.16, 95% confidence interval 0.05 to 0.53, p = 0.003) and body size (odds ratio = 0.36, 95% confidence interval 0.17 to 0.73; p = 0.005). No patient with a normal left ventricular end-diastolic dimension had a high DFT, whereas 14% (9 of 66) of those with left ventricular dilation had elevated thresholds. When the DFT cutoff was lowered to 15 J, as is necessary with some downsized pulse generators, an adequate threshold was observed in 84% of patients and the same 2 independent predictors of high thresholds were found. These results indicate that an adequate transvenous DFT can be predicted from simple clinical parameters.

Entities:  

Mesh:

Year:  1997        PMID: 9202352     DOI: 10.1016/s0002-9149(97)00210-5

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  9 in total

1.  A comparison of pectoral and abdominal transvenous defibrillator implantation: analysis of costs and outcomes.

Authors:  M R Gold; D Froman; N G Kavesh; R W Peters; A H Foster; S R Shorofsky
Journal:  J Interv Card Electrophysiol       Date:  1998-12       Impact factor: 1.900

2.  Incidence and clinical predictors of low defibrillation safety margin at time of implantable defibrillator implantation.

Authors:  Zhongwei Cheng; Mintu Turakhia; Ronald Lo; Anurag Gupta; Paul C Zei; Henry H Hsia; Amin Al-Ahmad; Paul J Wang
Journal:  J Interv Card Electrophysiol       Date:  2012-03-06       Impact factor: 1.900

3.  Subpectoral cardioverter-defibrillator implantation using a lateral approach.

Authors:  X F Costeas; P G Strembelas; D X Markou; C I Stefanadis; P K Toutouzas
Journal:  J Interv Card Electrophysiol       Date:  2000-12       Impact factor: 1.900

4.  A Systematic Review and Single-center Experience of Azygos Vein Defibrillator Lead Insertion.

Authors:  Ying Chi Yang; Suchith Shetty; Ketan Koranne; Aaqib Malik; Michael Giudici
Journal:  J Innov Card Rhythm Manag       Date:  2022-05-15

5.  How to Manage a High Defibrillation Threshold in ICD Patients: and Does it Really Matter?

Authors:  Maria Vittoria Matassini; Jeff S Healey
Journal:  Curr Treat Options Cardiovasc Med       Date:  2013-08

Review 6.  Implantable cardioverter-defibrillator in hypertrophic cardiomyopathy.

Authors:  Diego Jimenez Sanchez; Ignacio Fernández Lozano
Journal:  Glob Cardiol Sci Pract       Date:  2018-08-12

7.  High defibrillation threshold: the science, signs and solutions.

Authors:  Sony Jacob; Victorio Pidlaoan; Jaspreet Singh; Aditya Bharadwaj; Mehul B Patel; Antonio Carrillo
Journal:  Indian Pacing Electrophysiol J       Date:  2010-01-07

Review 8.  Rabbit models of cardiac mechano-electric and mechano-mechanical coupling.

Authors:  T Alexander Quinn; Peter Kohl
Journal:  Prog Biophys Mol Biol       Date:  2016-05-18       Impact factor: 3.667

9.  Incidence of ineffective safety margin testing (<10 J) and efficacy of routine subcutaneous array insertion during implantable cardioverter defibrillator implantation.

Authors:  Marc-Alexander Ohlow; Marcus Roos; Bernward Lauer; J Christoph Geller
Journal:  Indian Pacing Electrophysiol J       Date:  2016-02-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.