Strength and stability of posterior lumbar interbody fusion. Comparison of titanium fiber mesh implant and tricortical bone graft.

K Hoshijima1, R W Nightingale, J R Yu, W J Richardson, K D Harper, H Yamamoto, B S Myers.   

Abstract

STUDY
DESIGN: A paired comparison was done of the bending flexibility and compression strength of tricortical bone graft and titanium fiber mesh implants in a human cadaver model of posterior lumbar interbody fusion.
OBJECTIVES: To test the hypothesis that a titanium fiber mesh implant and a tricortical bone graft provide adequate and equal mechanical strength and stability in posterior lumbar interbody fusion constructs. SUMMARY OF BACKGROUND DATA: Although studies of posterior lumbar interbody fusion constructs have been performed, the authors are unaware of any study in which the strength and stability of a titanium fiber mesh implant are compared with those of tricortical bone graft for posterior lumbar interbody fusion in the human cadaver lumbar spine.
METHODS: Changes in neutral zone and range of motion were measured in a bending flexibility test before and after placement of posterior lumbar interbody fusion constructs. Tricortical bone graft and titanium fiber mesh implant construct stability than were compared in a paired analysis. The constructs than were loaded to failure to evaluate construct strength as a function of graft material and bone mineral density.
RESULTS: The posterior lumbar interbody fusion procedure produced statistically significant decreases in neutral zone when compared with the intact spine. No statistically significant differences in neutral zone, range of motion, or strength were detected between the two implants. Construct strength correlated strongly with bone mineral density.
CONCLUSIONS: Posterior lumbar interbody fusion procedures result in equal or improved acute stability for titanium fiber mesh implants and tricortical bone graft implants when used without additional posterior stabilization.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9201853     DOI: 10.1097/00007632-199706010-00002

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  6 in total

1.  In vitro properties of PLLA screws and novel bioabsorbable implant with elastic nucleus to replace intervertebral disc.

Authors:  V Ellä; M Kellomäki; P Törmälä
Journal:  J Mater Sci Mater Med       Date:  2005-07       Impact factor: 3.896

2.  Augmentation improves human cadaveric vertebral body compression mechanics for lumbar total disc replacement.

Authors:  Jonathon H Yoder; Joshua D Auerbach; Philip M Maurer; Erik M Erbe; Dean Entrekin; Richard A Balderston; Rudolf Bertagnoli; Dawn M Elliott
Journal:  Spine (Phila Pa 1976)       Date:  2010-04-20       Impact factor: 3.468

3.  In Vitro and In Vivo Comparison of Bone Growth Characteristics in Additive-Manufactured Porous Titanium, Nonporous Titanium, and Porous Tantalum Interbody Cages.

Authors:  Meng-Huang Wu; Ming-Hsueh Lee; Christopher Wu; Pei-I Tsai; Wei-Bin Hsu; Shin-I Huang; Tzu-Hung Lin; Kuo-Yi Yang; Chih-Yu Chen; Shih-Hao Chen; Ching-Yu Lee; Tsung-Jen Huang; Fang-Hei Tsau; Yen-Yao Li
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

Review 4.  Successful outcome of six-level cervicothoracic corpectomy and circumferential reconstruction: case report and review of literature on multilevel cervicothoracic corpectomy.

Authors:  Frank L Acosta; Henry E Aryan; Christopher P Ames
Journal:  Eur Spine J       Date:  2006-08-19       Impact factor: 3.134

5.  Combined posterior-anterior surgery for osteoporotic delayed vertebral fracture with neurologic deficit.

Authors:  Hiroaki Nakashima; Yasutsugu Yukawa; Keigo Ito; Masaaki Machino; Naoki Ishiguro; Fumihiko Kato
Journal:  Nagoya J Med Sci       Date:  2014-08       Impact factor: 1.131

6.  Total enbloc spondylectomy for metastatic high grade spinal tumors: Early results.

Authors:  Sanganagouda S Patil; Abhay M Nene
Journal:  Indian J Orthop       Date:  2016 Jul-Aug       Impact factor: 1.251

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.