Literature DB >> 9198019

An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery.

M J Murphy1.   

Abstract

A frameless radiosurgical treatment system has been developed by coupling an orthogonal pair of real-time x-ray cameras to a robotically manipulated linear accelerator to guide the therapy beam to treatment sites within a patient's cranium. The two cameras observe the position and orientation of the patient's head in the treatment system coordinate frame. An image registration algorithm compares the two real-time radiographs to a corresponding pair of digitally synthesized radiographs derived from a CT study of the patient. The algorithm determines all six degrees of translational and rotational difference between the position of the head in the CT coordinate frame and its position in the treatment room coordinate frame. This allows translation of treatment planning coordinates into treatment room coordinates without rigidly fixing the patient's head position during either the CT scan or treatment. In this paper the image registration algorithm is described and measurements of the precision and speed with which the process can determine the patient's position are reported. The tests have demonstrated translational uncertainty of 0.5-1.0 mm per axis and rotational uncertainty of 0.6-1.3 degrees per axis, accomplished in approximately 2 s elapsed time.

Entities:  

Mesh:

Year:  1997        PMID: 9198019     DOI: 10.1118/1.598005

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Clinical results of a pilot study on stereovision-guided stereotactic radiotherapy and intensity modulated radiotherapy.

Authors:  Shidong Li; Lawrence R Kleinberg; Daniele Rigamonti; Moody D Wharam; Abdul Rashid; Juan Jackson; David Djajaputra; Shenjen He; Tunisia Creasey; Theodore L DeWeese
Journal:  Technol Cancer Res Treat       Date:  2010-12

2.  Novel correction methods as alternatives for the six-dimensional correction in CyberKnife treatment.

Authors:  Osamu Suzuki; Hiroya Shiomi; Satoaki Nakamura; Fumitoshi Nakayama; Yasuo Yoshioka; Takehiro Inoue
Journal:  Radiat Med       Date:  2007-01-25

3.  Feasibility of respiratory motion-compensated stereoscopic X-ray tracking for bronchoscopy.

Authors:  Nikolas Leßmann; Daniel Drömann; Alexander Schlaefer
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-26       Impact factor: 2.924

4.  Vesselness-based 2D-3D registration of the coronary arteries.

Authors:  Daniel Ruijters; Bart M ter Haar Romeny; Paul Suetens
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-05-07       Impact factor: 2.924

5.  Initial evaluation of intrafraction motion using frameless CyberKnife VSI system.

Authors:  Alejandro Floriano; Icíar Santa-Olalla; Alberto Sanchez-Reyes
Journal:  Rep Pract Oncol Radiother       Date:  2013-04-16

6.  The correlation of tissue motion within the lung: implications on fiducial based treatments.

Authors:  Ryan L Smith; Deshan Yang; Andrew Lee; Martin L Mayse; Dan A Low; Parag J Parikh
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

7.  Clinical Assessment of 2D/3D Registration Accuracy in 4 Major Anatomic Sites Using On-Board 2D Kilovoltage Images for 6D Patient Setup.

Authors:  Guang Li; T Jonathan Yang; Hugo Furtado; Wolfgang Birkfellner; Åse Ballangrud; Simon N Powell; James Mechalakos
Journal:  Technol Cancer Res Treat       Date:  2014-09-15

8.  Evaluation of Image Enhancement Method on Target Registration Using Cone Beam CT in Radiation Therapy.

Authors:  Hui Yan; Ren Lei; Jackie Wu; Fu Di; Fang-Fang Yin
Journal:  Clin Med Oncol       Date:  2008-03-28

9.  A novel compound 6D-offset simulating phantom and quality assurance program for stereotactic image-guided radiation therapy system.

Authors:  Dennis Yuen Kan Ngar; Michael Lok-Man Cheung; Michael Koon-Ming Kam; Wai-Sang Poon; Anthony Tak-Cheung Chan
Journal:  J Appl Clin Med Phys       Date:  2014-11-04       Impact factor: 2.102

10.  Comparison of Skull Motions in Six Degrees of Freedom Between Two Head Supports During Frameless Radiosurgery by CyberKnife.

Authors:  Chen-Lin Kang; Shyh-Chang Liu; Jui-Chu Wang; Kuan-Cho Liao; Yu-Jie Huang; Fu-Min Fang; Tsung-I Liao; Kuo-Jung Juan; Chun-Chieh Huang
Journal:  Front Oncol       Date:  2018-09-04       Impact factor: 6.244

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.