Abstract

The accuracy of IOL calculation using the SRK II formula was studied in 515 cataract extractions with posterior chamber IOLs. All excessively myopic patients (8 patients) and those where we had predicted an emmetropic postoperative result, from a consecutive series of 994 patients, were included. Preoperatively the patients were divided into different groups according to their refractive status and the mean postoperative refraction was calculated in each group. The mean postoperative refraction increased almost linearly with increasing myopic status. The emmetropic group achieved a mean postoperative refraction of -0.6 D, whilst in the most myopic group mean refraction was -1.8 D. We believe that the SRK II formula is inaccurate for myopic eyes, and that new formulas are needed, taking into account all those factors that make up the dioptric power of an eye.

Entities:  

Mesh:

Year:  1997        PMID: 9197564     DOI: 10.1111/j.1600-0420.1997.tb00115.x

Source DB:  PubMed          Journal:  Acta Ophthalmol Scand        ISSN: 1395-3907


  6 in total

1.  Measurement of axial length of eyes with incomplete filling of silicone oil in the vitreous cavity using x ray computed tomography.

Authors:  Kazuo Takei; Yasuo Sekine; Fumiki Okamoto; Sachiko Hommura
Journal:  Br J Ophthalmol       Date:  2002-01       Impact factor: 4.638

2.  Light-adjustable lens: customizing correction for multifocality and higher-order aberrations.

Authors:  Christian A Sandstedt; Shiao H Chang; Robert H Grubbs; Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2006

3.  [Light adjustable lens. New options for customized correction of presbyopia].

Authors:  F H Hengerer; J Böcker; B H Dick; I Conrad-Hengerer
Journal:  Ophthalmologe       Date:  2012-07       Impact factor: 1.059

4.  Ray Tracing versus Thin-Lens Formulas for IOL Power Calculation Using Swept-Source Optical Coherence Tomography Biometry.

Authors:  Reza Ghaffari; Parisa Abdi; Alireza Moghaddasi; Somayeh Heidarzadeh; Hossein Ghahvhechian; Maryam Kasiri
Journal:  J Ophthalmic Vis Res       Date:  2022-04-29

5.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003

Review 6.  [The light-adjustable lens. Principles and clinical application].

Authors:  F H Hengerer; A C Mellein; S E Buchner; H B Dick
Journal:  Ophthalmologe       Date:  2009-03       Impact factor: 1.059

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.