Literature DB >> 9195428

Development of a surface replacement arthroplasty for proximal interphalangeal joints.

R L Linscheid1, P M Murray, M A Vidal, R D Beckenbaugh.   

Abstract

Sixty-six surface replacement proximal interphalangeal prostheses with a CrCo proximal and an ultrahigh-molecular-weight polyethylene distal component were used in the hands of 47 patients (mean age, 58 years) over a 14-year period. There were 37 fingers with degenerative arthrosis, 16 with traumatic arthrosis, and 13 with rheumatoid arthritis. The mean follow-up period was 4.5 years (range, 1-14 years). The results based on pain relief, motion, and deformity were good in 32 fingers, fair in 19, and poor in 15. Poor results occurred primarily in fingers with previous extensive injury or static deformity. Results with a dorsal approach were better than those with a lateral or palmar approach. Component loosening at the bone-cement junction beyond a minimal radiolucent line was seen in one late x-ray. Results in individuals changed little after the first year of follow-up care, but results overall improved during the course of the study, perhaps because of improvements in surgical technique and experience.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9195428     DOI: 10.1016/S0363-5023(97)80165-7

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  13 in total

Review 1.  Advances in Proximal Interphalangeal Joint Arthroplasty: Biomechanics and Biomaterials.

Authors:  Andy F Zhu; Paymon Rahgozar; Kevin C Chung
Journal:  Hand Clin       Date:  2018-05       Impact factor: 1.907

2.  Pyrocarbon finger joint implant: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2004-03-01

3.  Outcomes of Surface Replacement Proximal Interphalangeal Joint Arthroplasty Using the Self Locking Finger Joint Implant: Minimum Two Years Follow-up.

Authors:  Issei Komatsu; Yoshiya Arishima; Hirotomo Shibahashi; Toshihito Yamaguchi; Yoshitaka Minamikawa
Journal:  Hand (N Y)       Date:  2017-09-16

4.  Surface Replacement Proximal Interphalangeal Joint Arthroplasty: A Case Series.

Authors:  Pieter W Jordaan; Duncan McGuire; Michael W Solomons
Journal:  Hand (N Y)       Date:  2018-03-05

5.  Conical, radiographic, and patient-reported results of surface replacing proximal interphalangeal joint arthroplasty of the hand.

Authors:  Mohana Amirtharajah; Duretti Fufa; Nina Lightdale; Andew Weiland
Journal:  Iowa Orthop J       Date:  2011

6.  [The role of endoprostheses in the scope of hand surgery. Endoprostheses vs. traditional surgical procedures].

Authors:  W Daecke; N Streich; S Schneider; A-K Martini
Journal:  Unfallchirurg       Date:  2005-02       Impact factor: 1.000

7.  Outcomes of pyrolytic carbon arthroplasty for the proximal interphalangeal joint.

Authors:  Kevin C Chung; Ashwin N Ram; Melissa J Shauver
Journal:  Plast Reconstr Surg       Date:  2009-05       Impact factor: 4.730

8.  Surface Replacement Arthroplasty Using a Volar Approach for Osteoarthritis of Proximal Interphalangeal Joint: Results After a Minimum 5-Year Follow-up.

Authors:  Ken Shirakawa; Masahiko Shirota
Journal:  Hand (N Y)       Date:  2018-07-17

9.  Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state.

Authors:  Harvinder Singh; Joseph J Dias
Journal:  Indian J Plast Surg       Date:  2011-05

10.  Long-term Outcomes of MCP Surface Replacement Arthroplasty in Patients With Rheumatoid Arthritis.

Authors:  Matthew R Claxton; Eric R Wagner; Marco Rizzo
Journal:  Hand (N Y)       Date:  2020-06-02
View more