Literature DB >> 9194133

SPECT scatter modelling in non-uniform attenuating objects.

F J Beekman1, J M den Harder, M A Viergever, P P van Rijk.   

Abstract

SPECT quantitation and image contrast are degraded by photon scatter. Water equivalent depths (WEDs) have been used by several investigators to model scatter responses in non-uniform attenuators. The drawback of this approach is the occurrence of undesired fluctuations in the shape of the scatter responses, as is shown by measurements. An improvement of the WED method is presented, based on the assumption that only a part of the scattering object (the region in the 'scatter cone') contributes significantly to the detected scatter events. The remaining part of the object is treated as a uniform medium. The extension of the WED method with extra-conical invariance (WEDECI) is evaluated by projection measurements of a phantom with a 99mTc source. Shapes of scatter responses predicted by the WEDECI method are found to agree better with the measurements than those predicted by conventional WEDs.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9194133     DOI: 10.1088/0031-9155/42/6/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

Review 1.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

2.  Effect of errors in the system matrix on maximum a posteriori image reconstruction.

Authors:  Jinyi Qi; Ronald H Huesman
Journal:  Phys Med Biol       Date:  2005-07-06       Impact factor: 3.609

Review 3.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

Review 4.  Quantitative myocardial perfusion SPECT.

Authors:  B M Tsui; E C Frey; K J LaCroix; D S Lalush; W H McCartney; M A King; G T Gullberg
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

5.  The effect of volume-of-interest misregistration on quantitative planar activity and dose estimation.

Authors:  N Song; B He; E C Frey
Journal:  Phys Med Biol       Date:  2010-08-27       Impact factor: 3.609

6.  Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurements.

Authors:  Michel S Tohme; Jinyi Qi
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.