Glutaraldehyde-resistant Mycobacterium chelonae from endoscope washer disinfectors.

P A Griffiths1, J R Babb, C R Bradley, A P Fraise.   

Abstract

Glutaraldehyde is used to disinfect flexible and other heat-sensitive endoscopes often with the aid of automated systems. Mycobacterium chelonae is being isolated with increasing frequency from these washer disinfectors and processed endoscopes. This has, on occasions, led to misdiagnosis and iatrogenic infections. Recent reports suggest that disinfecting machines, on a sessional or regular basis, with 2% glutaraldehyde may have selected and therefore encouraged the growth of strains of Myco. chelonae, possibly in biofilm, with decreasing susceptibility to glutaraldehyde. In view of this, the resistance of three strains of Myco. chelonae var. chelonae (the type strain NCTC 946 and two machine isolates) was tested against 2% glutaraldehyde and a wide range of alternative disinfectants. Disinfectants tested were a chlorine releasing agent, sodium dichloroisocyanurate at 1000 ppm and 10,000 ppm av Cl, 0.35% peracetic acid (NuCidex, Johnson & Johnson), 70% industrial methylated spirit (IMS), 1% peroxygen compound ('Virkon', Antec International) and 10% succine dialdehyde ('Gigasept', Sanofi Winthrop). Suspension and carrier tests were carried out in the presence and absence of an organic load. Results showed the type strain, which had not been exposed to the selective pressure of disinfectant usage, to be very sensitive to most disinfectants with the exception of 1% Virkon. The washer disinfector isolates, on the other hand, were extremely resistant to 2% glutaraldehyde and showed greater resistance to 1% Virkon and 1000 ppm NaDCC. Purchasing machines in which the entire fluid pathways, including those for delivering rinse water, are disinfected with an appropriate agent during each cycle are preferred. If this is not possible then sessional cleaning and disinfection at the start of each day and regular maintenance should prevent biofilm formation and contamination with disinfectant-resistant strains of mycobacteria. In addition to machine disinfection, the use of sterile or bacteria-free (filtered < 0.45 microm) water is essential for bronchoscopes and all invasive endoscopes. If there is doubt that the effectiveness of the machine disinfection procedure or water quality, the channels and surfaces of endoscopes may be rinsed with 70% IMS after automated processing.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9190297     DOI: 10.1046/j.1365-2672.1997.00171.x

Source DB:  PubMed          Journal:  J Appl Microbiol        ISSN: 1364-5072            Impact factor:   3.772


  18 in total

1.  British Thoracic Society guidelines on diagnostic flexible bronchoscopy.

Authors: 
Journal:  Thorax       Date:  2001-03       Impact factor: 9.139

2.  Resistance of Acanthamoeba cysts to disinfection treatments used in health care settings.

Authors:  Céline Coulon; Anne Collignon; Gerald McDonnell; Vincent Thomas
Journal:  J Clin Microbiol       Date:  2010-06-02       Impact factor: 5.948

3.  Pericardial tissue for cardiovascular application: an in-vitro evaluation of established and advanced production processes.

Authors:  L Grefen; F König; M Grab; C Hagl; N Thierfelder
Journal:  J Mater Sci Mater Med       Date:  2018-11-03       Impact factor: 3.896

4.  Hospital infections in Birmingham, England, in the 19th and 20th centuries.

Authors:  Christina R Bradley; Gaj Ayliffe
Journal:  J Infect Prev       Date:  2018-08-22

5.  Complications of laparoscopic inguinal herniorrhaphy including one case of atypical mycobacterial infection.

Authors:  Julio C U Coelho; Christiano M P Claus; João Carlos Michelotto; Fabiana Marques Fernandes; Christian Lopez Valle; Leonardo Dudeque Andriguetto; Antonio C L Campos
Journal:  Surg Endosc       Date:  2010-04-08       Impact factor: 4.584

6.  Disinfectant Susceptibility Profiling of Glutaraldehyde-Resistant Nontuberculous Mycobacteria.

Authors:  Winona Burgess; Alyssa Margolis; Sara Gibbs; Rafael Silva Duarte; Mary Jackson
Journal:  Infect Control Hosp Epidemiol       Date:  2017-05-02       Impact factor: 3.254

7.  Aldehyde-resistant mycobacteria bacteria associated with the use of endoscope reprocessing systems.

Authors:  Christopher W Fisher; Anthony Fiorello; Diana Shaffer; Mary Jackson; Gerald E McDonnell
Journal:  Am J Infect Control       Date:  2012-02-10       Impact factor: 2.918

8.  Analysis of a panel of rapidly growing mycobacteria for resistance to aldehyde-based disinfectants.

Authors:  Mary Ann De Groote; Sara Gibbs; Vinicius Calado Nogueira de Moura; Winona Burgess; Kris Richardson; Shannon Kasperbauer; Nancy Madinger; Mary Jackson
Journal:  Am J Infect Control       Date:  2014-08       Impact factor: 2.918

9.  Role of porins in the susceptibility of Mycobacterium smegmatis and Mycobacterium chelonae to aldehyde-based disinfectants and drugs.

Authors:  Zuzana Svetlíková; Henrieta Skovierová; Michael Niederweis; Jean-Louis Gaillard; Gerald McDonnell; Mary Jackson
Journal:  Antimicrob Agents Chemother       Date:  2009-07-06       Impact factor: 5.191

10.  Tolerance to Glutaraldehyde in Escherichia coli Mediated by Overexpression of the Aldehyde Reductase YqhD by YqhC.

Authors:  Beatriz Merchel Piovesan Pereira; Muhammad Adil Salim; Navneet Rai; Ilias Tagkopoulos
Journal:  Front Microbiol       Date:  2021-06-23       Impact factor: 5.640

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.