Literature DB >> 9189147

Right and left ventricular volume and ejection fraction by tomographic gated blood-pool scintigraphy.

B B Chin1, D C Bloomgarden, W Xia, H J Kim, Z A Fayad, V A Ferrari, J A Berlin, L Axel, A Alavi.   

Abstract

UNLABELLED: Tomographic techniques separate overlying structures, permitting measurements of absolute ventricular volumes. The purpose of this study was to determine absolute right and left ventricular volume and ejection fraction measurements with tomographic gated equilibrium blood-pool scintigraphy (TMUGA) compared to MRI and conventional planar scintigraphy.
METHODS: Eighteen patients were studied. Ventricular volumes for TMUGA and MRI were calculated by modified Simpson's rule. TMUGA regions were defined by constraints including phase analysis, intensity threshold and visual inspection. MRI studies were acquired with a fast gradient-echo, ECG-gated, breath-hold technique and boundaries were defined by a semiautomated contour method. Conventional gated first-pass radionuclide angiography (FP) and planar gated equilibrium blood-pool scintigraphy (PMUGA) were performed for RV EF and LV EF, respectively.
RESULTS: TMUGA absolute right ventricular volumes showed excellent-correlation with MRI for both right ventricular volumes (r = 0.91, slope = 0.90, s.e.e. = 15.7) and left ventricular volumes (r = 0.96, slope = 0.88, s.e.e. = 18.2). For left ventricular ejection fraction, TMUGA also showed excellent correlation with MRI (r = 0.94, slope = 1.10, s.e.e. = 9.0) and planar MUGA (r = 0.97, slope = 1.23, s.e.e. = 6.2). For right ventricular ejection fraction, TMUGA showed good correlation with both MRI (r = 0.88, slope = 0.79, s.e.e. = 6.0) and first-pass planar scintigraphy (r = 0.86, slope = 1.2, s.e.e. = 7.9).
CONCLUSION: Tomographic gated blood-pool scintigraphy absolute right and left ventricular volumes and ejection fractions show good correlation with accepted techniques. Further studies are necessary to define the reproducibility of this method.

Entities:  

Mesh:

Year:  1997        PMID: 9189147

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  20 in total

1.  Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT.

Authors:  S D Van Kriekinge; D S Berman; G Germano
Journal:  J Nucl Cardiol       Date:  1999 Sep-Oct       Impact factor: 5.952

2.  Evaluation of right ventricular function by NuSMUGA software: gated blood-pool SPECT vs. first-pass radionuclide angiography.

Authors:  R H J A Slart; L Poot; D A Piers; D J van Veldhuisen; P L Jager
Journal:  Int J Cardiovasc Imaging       Date:  2003-10       Impact factor: 2.357

3.  Model dependence of gated blood pool SPECT ventricular function measurements.

Authors:  Kenneth Nichols; Naeem Humayun; Pieter De Bondt; Stijn Vandenberghe; Olakunle O Akinboboye; Steven R Bergmann
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

4.  Equilibrium radionuclide angiocardiography.

Authors:  James R Corbett; Olakunle O Akinboboye; Stephen L Bacharach; Jeffrey S Borer; Elias H Botvinick; E Gordon DePuey; Edward P Ficaro; Christopher L Hansen; Milena J Henzlova; Serge Van Kriekinge
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

5.  Clinical validation of the gated blood pool SPECT QBS processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D-echocardiography.

Authors:  Marcus Hacker; Xaver Hoyer; Sandra Kupzyk; Christian La Fougere; Johann Kois; Hans-Ulrich Stempfle; Reinhold Tiling; Klaus Hahn; Stefan Störk
Journal:  Int J Cardiovasc Imaging       Date:  2005-11-22       Impact factor: 2.357

Review 6.  SPECT radionuclide angiography: it is time for a consensus statement.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11       Impact factor: 9.236

7.  Operator-interactive method for simultaneous measurement of left and right ventricular volumes and ejection fraction by tomographic electrocardiography-gated blood pool radionuclide ventriculography.

Authors:  Ian P Clements; Benjamin Brinkmann; Brian P Mullan; Michael K O'Connor; Jerome F Breen; Christopher G A McGregor
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

8.  EANM/ESC guidelines for radionuclide imaging of cardiac function.

Authors:  B Hesse; T B Lindhardt; W Acampa; C Anagnostopoulos; J Ballinger; J J Bax; L Edenbrandt; A Flotats; G Germano; T Gmeiner Stopar; P Franken; A Kelion; A Kjaer; D Le Guludec; M Ljungberg; A F Maenhout; C Marcassa; J Marving; F McKiddie; W M Schaefer; L Stegger; R Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-04       Impact factor: 9.236

9.  Assessment of pulmonary thromboendarterectomy by tomographic electrocardiogram-gated equilibrium radionuclide angiocardiography compared with electron beam computed tomography.

Authors:  Ian P Clements; Brian P Mullan; Michael K O'Connor; Jerome F Breen; Christopher G A McGregor
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

10.  Quantitative gated blood pool SPECT for the assessment of coronary artery disease at rest.

Authors:  M W Groch; R C Marshall; W D Erwin; D J Schippers; C A Barnett; E M Leidholdt
Journal:  J Nucl Cardiol       Date:  1998 Nov-Dec       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.