Literature DB >> 9180321

The interosseous membrane in radio-ulnar dissociation.

A L Wallace1, W R Walsh, M van Rooijen, J S Hughes, D H Sonnabend.   

Abstract

In severe forearm injuries, the diagnosis of disruption of the interosseous membrane is frequently delayed and sometimes missed, giving difficulties in the salvage of forearm stability. We studied the structure and function of the interosseous membrane in 11 cadaver preparations, using mechanical and histological analysis. Seven of the specimens tested in uniaxial tension sustained a mid-substance tear of the central band of the membrane at a mean peak load of 1038 +/- 308 N. The axial stiffness was 190 +/- 44 N/mm with elongation to failure of 10.34 +/- 2.46 mm. These results provide criteria for the evaluation of reconstructive methods. A preliminary clinical investigation of the use of ultrasound suggests that this may be of value in the screening of patients with complex fractures of the forearm, and for investigating the natural history of tears of the interosseous membrane.

Entities:  

Mesh:

Year:  1997        PMID: 9180321     DOI: 10.1302/0301-620x.79b3.7142

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  9 in total

Review 1.  [Diagnosis and treatment of the Essex-Lopresti lesion. Literature review and four case reports].

Authors:  A Doser; M Markmiller; P C Strohm; N P Südkamp
Journal:  Unfallchirurg       Date:  2006-07       Impact factor: 1.000

2.  The "muscular hernia sign": an original ultrasonographic sign to detect lesions of the forearm's interosseous membrane.

Authors:  Marc Soubeyrand; Clarisse Lafont; Christophe Oberlin; Welby France; Ivan Maulat; Renaud Degeorges
Journal:  Surg Radiol Anat       Date:  2006-07-01       Impact factor: 1.246

3.  Forearm interosseous membrane trauma: MRI diagnostic criteria and injury patterns.

Authors:  Joseph C McGinley; Neil Roach; Brendon C Hopgood; Karl Limmer; Scott H Kozin
Journal:  Skeletal Radiol       Date:  2006-02-22       Impact factor: 2.199

4.  Ligamentoplasty of the forearm interosseous membrane using the semitendinosus tendon: anatomical study and surgical procedure.

Authors:  M Soubeyrand; C Oberlin; C Dumontier; Z Belkheyar; C Lafont; R Degeorges
Journal:  Surg Radiol Anat       Date:  2006-02-11       Impact factor: 1.246

Review 5.  The role of ultrasound and magnetic resonance imaging in the evaluation of the forearm interosseous membrane. A review.

Authors:  Juan Rodriguez-Martin; Juan Pretell-Mazzini
Journal:  Skeletal Radiol       Date:  2011-05-20       Impact factor: 2.199

6.  Semitendinosus ligamentoplasty of the forearm interosseous membrane in a case of Essex-Lopresti syndrome.

Authors:  Christophe Oberlin; Zoubir Belkheyar; Marc Soubeyrand; France Welby; Renaud Degeorges
Journal:  Eur J Orthop Surg Traumatol       Date:  2006-03-24

7.  Interosseous Membrane of the Forearm.

Authors:  Robert Matthias; Thomas W Wright
Journal:  J Wrist Surg       Date:  2016-06-13

8.  Radial shortening following a fracture of the proximal radius.

Authors:  Andrew D Duckworth; Bruce S Watson; Elizabeth M Will; Brad A Petrisor; Phillip J Walmsley; Charles M Court-Brown; Margaret M McQueen
Journal:  Acta Orthop       Date:  2011-04-19       Impact factor: 3.717

9.  Open reduction combined with CORA-based osteotomy of the ulna in the treatment of missed Bado type I Monteggia injury: A retrospective study of 5 cases.

Authors:  Zhenyu Xu; Yuchan Li; Zhigang Wang; Haiqing Cai
Journal:  Medicine (Baltimore)       Date:  2017-11       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.