Literature DB >> 9178249

Dispersion in magnetization transfer contrast at a given specific absorption rate due to variations of RF pulse parameters in the magnetization transfer preparation.

Y Wang1, T M Grist, C A Mistretta.   

Abstract

The effects of RF pulse parameters on magnetization transfer contrast (MTC) were investigated using a magnetization prepared segmented fast gradient echo sequence. MTC was found not to be uniquely determined by the specific absorption rate (SAR). RF pulse parameters (RF amplitude, number of RF pulses and RF duration) also affect MTC. There can be 40% variation in MTC due to differences in RF parameters at SAR = 1 W/kg for a 70-kg subject. Increasing the number of RF pulses is a more efficient way to increase MTC than increasing RF amplitude. This phenomenon is likely caused by the fact that the time scale for magnetization transfer between the free and restricted proton pools is on the same order or longer than the duration of the MT pulse. Accordingly, increase in the MT pulse duration by increasing the number of RF pulses in the MT pulse allows more effective magnetization transfer. Such information can be used as a guide to select RF pulse parameters for a magnetization transfer (MT) pulse. An off-resonance MT pulse designed under this guide for coronary MR angiography improved the depiction of distal vessels.

Entities:  

Mesh:

Year:  1997        PMID: 9178249     DOI: 10.1002/mrm.1910370622

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  B1 mapping by Bloch-Siegert shift.

Authors:  Laura I Sacolick; Florian Wiesinger; Ileana Hancu; Mika W Vogel
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

2.  Optimization of on-resonant magnetization transfer contrast in coronary vein MRI.

Authors:  Christian T Stoeck; Peng Hu; Dana C Peters; Kraig V Kissinger; Beth Goddu; Lois Goepfert; Long Ngo; Warren J Manning; Sebastian Kozerke; Reza Nezafat
Journal:  Magn Reson Med       Date:  2010-12       Impact factor: 4.668

3.  Fast multislice pH-weighted chemical exchange saturation transfer (CEST) MRI with Unevenly segmented RF irradiation.

Authors:  Phillip Zhe Sun; Jerry S Cheung; Enfeng Wang; Thomas Benner; A Gregory Sorensen
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

4.  Fast magnetization transfer and apparent T1 imaging using a short saturation pulse with and without inversion preparation.

Authors:  Tae Kim; Wanyong Shin; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.