Literature DB >> 9178242

Background suppression with multiple inversion recovery nulling: applications to projective angiography.

S Mani1, J Pauly, S Conolly, C Meyer, D Nishimura.   

Abstract

We have developed a technique to accurately null the longitudinal magnetization (Mz) of background material. This suppression involves first saturating the longitudinal magnetization (Mz) of a region, and then applying several nonselective inversions. The inversions are timed relative to the saturation such that Mz is nulled across a broad range of T1 at a predetermined time after the initial saturation. B1 and B0 inhomogeneity, which could lead to inaccurate suppression, are dealt with by the combination of a multiple tip saturation sequence and four adiabatic inversion pulses. The suppression sequence can be used to form projective angiograms by selectively tagging the imaging region with the saturation pulse. After the inversions are played out, a projection taken through the tag region when Mz is nulled will only contain signal from blood that has flown into the region after the saturation. Since only two dimensions are acquired, the technique can acquire gated projection angiograms in reasonable scan times. Representative inflow MIR angiograms of the carotid arteries and renal arteries show excellent background suppression.

Mesh:

Year:  1997        PMID: 9178242     DOI: 10.1002/mrm.1910370615

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Reduction of CSF artifacts on FLAIR images by using adiabatic inversion pulses.

Authors:  J V Hajnal; A Oatridge; A H Herlihy; G M Bydder
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

Review 2.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

3.  Blood flow MRI of the human retina/choroid during rest and isometric exercise.

Authors:  Yi Zhang; Oscar San Emeterio Nateras; Qi Peng; Carlos A Rosende; Timothy Q Duong
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-06-28       Impact factor: 4.799

4.  Time spatial labeling inversion pulse cerebral MR angiography without subtraction by use of dual inversion recovery background suppression.

Authors:  Yoshiyuki Ishimori; Masahiko Monma; Hiraku Kawamura; Tomoko Miyata
Journal:  Radiol Phys Technol       Date:  2010-12-01

Review 5.  Principles and methods for automatic and semi-automatic tissue segmentation in MRI data.

Authors:  Lei Wang; Teodora Chitiboi; Hans Meine; Matthias Günther; Horst K Hahn
Journal:  MAGMA       Date:  2016-01-11       Impact factor: 2.310

6.  Optimization of background suppression for arterial spin labeling perfusion imaging.

Authors:  Nasim Maleki; Weiying Dai; David C Alsop
Journal:  MAGMA       Date:  2011-10-19       Impact factor: 2.310

7.  Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine.

Authors:  Jordin D Green; Reed A Omary; Brian E Schirf; Richard Tang; Biao Lu; James A Gehl; J Jenny Huang; James C Carr; F Scott Pereles; Debiao Li
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

8.  Three-dimensional contrast-enhanced steady-state free precession for improved catheter-directed coronary magnetic resonance angiography.

Authors:  Jordin D Green; Reed A Omary; Brian E Schirf; Richard Tang; James C Carr; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2005-09       Impact factor: 4.813

9.  Variable flip angle three-dimensional fast spin-echo sequence combined with outer volume suppression for imaging trabecular bone structure of the proximal femur.

Authors:  Misung Han; Ko Chiba; Suchandrima Banerjee; Julio Carballido-Gamio; Roland Krug
Journal:  J Magn Reson Imaging       Date:  2014-06-23       Impact factor: 4.813

Review 10.  Noise concerns and post-processing procedures in cerebral blood flow (CBF) and cerebral blood volume (CBV) functional magnetic resonance imaging.

Authors:  Manus J Donahue; Meher R Juttukonda; Jennifer M Watchmaker
Journal:  Neuroimage       Date:  2016-09-11       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.