Literature DB >> 9178230

Improved sensitivity to overlapping multiplet signals in in vivo proton spectroscopy using a multiecho volume selective (CPRESS) experiment.

J Hennig1, T Thiel, O Speck.   

Abstract

A method for volume selective proton spectroscopy is presented based on a multiecho sequence with short refocusing interval tcp. It is demonstrated, that by appropriate choice of tcp on the order of 4-6 ms, signals from overlapping multiplets like the glutamine and glutamate (Glu/Gln) resonances in spectra of the human brain are considerably increased compared with a conventional PRESS volume selection scheme. Thus proton spectra from J-coupled multiplet signals can be acquired with TE on the order of 20-30 ms avoiding the baseline problems arising at shorter echo times due to broad resonances. This allows to selectively acquire spectra from substances with longer T2 without the confounding effects from J-coupling occurring in conventional volume selection techniques.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9178230     DOI: 10.1002/mrm.1910370603

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  J-refocused coherence transfer spectroscopic imaging at 7 T in human brain.

Authors:  J W Pan; N Avdievich; H P Hetherington
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

2.  GAVA: spectral simulation for in vivo MRS applications.

Authors:  Brian J Soher; Karl Young; Aaron Bernstein; Zakaria Aygula; Andrew A Maudsley
Journal:  J Magn Reson       Date:  2007-01-12       Impact factor: 2.229

Review 3.  Glutamate and glutamine: a review of in vivo MRS in the human brain.

Authors:  Saadallah Ramadan; Alexander Lin; Peter Stanwell
Journal:  NMR Biomed       Date:  2013-10-04       Impact factor: 4.044

4.  Observation of coupled 1H metabolite resonances at long TE.

Authors:  Brian J Soher; Pradip M Pattany; Gerald B Matson; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2005-06       Impact factor: 4.668

5.  Improved myo-inositol detection through Carr-Purcell PRESS: a tool for more sensitive mild cognitive impairment diagnosis.

Authors:  Ileana Hancu; Robert Gillen; John Cowan; Earl A Zimmerman
Journal:  Magn Reson Med       Date:  2011-01-10       Impact factor: 4.668

6.  High-resolution, 3D multi-TE 1 H MRSI using fast spatiospectral encoding and subspace imaging.

Authors:  Zepeng Wang; Yahang Li; Fan Lam
Journal:  Magn Reson Med       Date:  2021-11-09       Impact factor: 3.737

7.  Effect of Carr-Purcell refocusing pulse trains on transverse relaxation times of metabolites in rat brain at 9.4 Tesla.

Authors:  Dinesh Kumar Deelchand; Pierre-Gilles Henry; Małgorzata Marjańska
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

8.  Numerical simulations of localized high field 1H MR spectroscopy.

Authors:  Lana G Kaiser; Karl Young; Gerald B Matson
Journal:  J Magn Reson       Date:  2008-08-28       Impact factor: 2.229

9.  Optimized glutamate detection at 3T.

Authors:  Ileana Hancu
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

10.  Which pulse sequence is optimal for myo-inositol detection at 3T?

Authors:  Ileana Hancu
Journal:  NMR Biomed       Date:  2009-05       Impact factor: 4.044

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.