Geometric analysis of light-field position of a multileaf collimator with curved ends.

A L Boyer1, S Li.   

Abstract

The purpose of this work was to analyze the difference between the light-field edge and the radiation field edge produced by multileaf collimator (MLC) leaves that are constructed with rounded ends. A formula was derived using three-dimensional geometry predicting the location of the ideal point-source light-field edge relative to the geometric projection of the tip of the rounded leaf end. The theoretical edge of the radiation field for a point source was also calculated along the projection of a chord whose length was one Half-Value Thickness (HVT). Analytic solutions were found for the radiation-field edge and the transmission penumbra. The displacement of the light-field edge relative to the projection of the leaf tip varied from 0 mm for the leaf tip projected onto the central axis to approximately 3.2 mm for the leaf tip projected to 20 cm off the central axis. The light-field edge was always displaced into the unblocked area. The location of the projection of the 1 HVT chord was displaced from the light-field edge by a small and essentially constant distance (approximately 0.3 mm) for all field sizes. The transmission penumbra (80%-20%) was about 1.2 mm for all leaf positions. The calibration of the leaf position must account for the nonlinear relationship between the leaf-tip projection and the light-field (or radiation-field) edge.

Mesh:

Year:  1997        PMID: 9167168     DOI: 10.1118/1.597996

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Optimizing the MLC model parameters for IMRT in the RayStation treatment planning system.

Authors:  Shifeng Chen; Byong Yong Yi; Xiaocheng Yang; Huijun Xu; Karl L Prado; Warren D D'Souza
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

2.  Rounded leaf end modeling in Pinnacle VMAT treatment planning for fixed jaw linacs.

Authors:  Lori A Young; Fei Yang; Ning Cao; Juergen Meyer
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

3.  The dosimetric impact of control point spacing for sliding gap MLC fields.

Authors:  Benjamin J Zwan; Jonathan Hindmarsh; Erin Seymour; Kankean Kandasamy; Kirbie Sloan; Rajesakar David; Christopher Lee
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

4.  Static MLC transmission simulation using two-dimensional ray tracing.

Authors:  David P Adam; Bryan P Bednarz; Sean P Frigo
Journal:  J Appl Clin Med Phys       Date:  2022-05-20       Impact factor: 2.243

5.  Rounded leaf end effect of multileaf collimator on penumbra width and radiation field offset: an analytical and numerical study.

Authors:  Dong Zhou; Hui Zhang; Peiqing Ye
Journal:  Radiol Oncol       Date:  2015-08-21       Impact factor: 2.991

6.  Dosimetric characteristics of dual-layer multileaf collimation for small-field and intensity-modulated radiation therapy applications.

Authors:  Yaxi Liu; Chengyu Shi; Patricia Tynan; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2008-03-31       Impact factor: 2.102

  6 in total