Literature DB >> 9165397

Forces and moments generated at the dental incisors during forceful biting in humans.

T W Korioth1, T W Waldron, A Versluis, J K Schulte.   

Abstract

A miniature load sensor capable of measuring all forces and all moments simultaneously at a single location in space was used to assess the magnitude and direction of loads that affect the dental incisors during forceful, static biting. While prior approaches have not measured all necessary six degrees of freedom during biting, the complete set of loads is needed to serve as realistic boundary conditions for analytical or computational models of mandibular mechanics. Four subjects were asked to perform controlled and repetitive edge-to-edge incisal biting activities. Customized devices were used to rigidly hold the load sensor in place at pre-specified tooth separations of less than 1 mm. The results yielded force resultants with a magnitude range of 24.5 to 28.4 N. This range was intentionally limited in magnitude to avoid damage to the internal strain gauge assembly of the sensor. In all cases, the highest force component was oriented upwards. An additional simultaneous moment resultant (range: 8.9-17.0 N cm) with a main moment component oriented backwards and downwards towards the oral cavity was also detected. These data suggest that in order for the biting loads to be composed of six DOF, the remaining forces acting on the mandibular force system (i.e. muscular and/or articular) may indeed be non-coplanar and non-concurrent. Although useful for static biting activities, the bulk of the sensor would probably preclude meaningful measurements during dynamic events such as chewing or swallowing.

Entities:  

Mesh:

Year:  1997        PMID: 9165397     DOI: 10.1016/s0021-9290(96)00182-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns.

Authors:  Verena Preis; Thomas Dowerk; Michael Behr; Carola Kolbeck; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2013-07-12       Impact factor: 3.573

2.  Biomechanical properties of CAD/CAM-individualized nickel-titanium lingual retainers: an in vitro study.

Authors:  Stephan Christian Möhlhenrich; Fabian Jäger; Andreas Jäger; Pascal Schumacher; Michael Wolf; Ulrike Fritz; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2018-07-16       Impact factor: 1.938

3.  Fatigue and Fracture Resistance Testing of Polyether Ether Ketone (PEEK) Implant Abutments in an Ex Vivo Chewing Simulator Model.

Authors:  Babak Saravi; Anselm Flohr; Sebastian B Patzelt; Benedikt C Spies; Derek Hazard; Ralf J Kohal
Journal:  Materials (Basel)       Date:  2022-10-06       Impact factor: 3.748

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.