T S Johnson1, J L Engstrom, D K Gelhar. 1. Department of Maternal-Child Nursing, College of Nursing, University of Illinois at Chicago 60612, USA.
Abstract
BACKGROUND: The reliability of anthropometric measurements of term infants has not been studied sufficiently to determine if these measurements are reliable enough to be used in clinical practice and research. This study described the intra- and interexaminer reliability of the following anthropometric measurements: weight (WT), head circumference (HC), chest circumference (CC), abdominal circumference (AC), mid-arm circumference (MAC), and length. METHODS: A convenience sample of 50 clinically stable term infants was studied. Two examiners obtained the six measurements twice using blank tape measures. The order of examiners was randomized and the examiners were masked to their own and the other examiners' measurements. RESULTS: The intraexaminer mean absolute differences were as follows: WT = 1.88, 3.28 g; HC = 0.29, 0.29 cm; CC = 0.50, 0.78 cm; AC = 0.71, 0.77 cm; MAC = 0.36, 0.39 cm; length = 0.92, 1.18 cm. The interexaminer mean absolute differences were as follows: WT = 1.94, 1.66 g; HC = 0.37, 0.36 cm; CC = 0.59, 0.72 cm; AC = 0.99, 0.77 cm; MAC = 0.41, 0.57 cm; length = 1.57, 1.47 cm. CONCLUSIONS: These findings indicate that intraexaminer differences tended to be smaller than interexaminer differences for all measures except weight, which remained stable for intra- and interexaminer comparisons. These findings also suggest that weight and head circumference were the most reliable measures, whereas length and mid-arm circumference were the least reliable measures.
RCT Entities:
BACKGROUND: The reliability of anthropometric measurements of term infants has not been studied sufficiently to determine if these measurements are reliable enough to be used in clinical practice and research. This study described the intra- and interexaminer reliability of the following anthropometric measurements: weight (WT), head circumference (HC), chest circumference (CC), abdominal circumference (AC), mid-arm circumference (MAC), and length. METHODS: A convenience sample of 50 clinically stable term infants was studied. Two examiners obtained the six measurements twice using blank tape measures. The order of examiners was randomized and the examiners were masked to their own and the other examiners' measurements. RESULTS: The intraexaminer mean absolute differences were as follows: WT = 1.88, 3.28 g; HC = 0.29, 0.29 cm; CC = 0.50, 0.78 cm; AC = 0.71, 0.77 cm; MAC = 0.36, 0.39 cm; length = 0.92, 1.18 cm. The interexaminer mean absolute differences were as follows: WT = 1.94, 1.66 g; HC = 0.37, 0.36 cm; CC = 0.59, 0.72 cm; AC = 0.99, 0.77 cm; MAC = 0.41, 0.57 cm; length = 1.57, 1.47 cm. CONCLUSIONS: These findings indicate that intraexaminer differences tended to be smaller than interexaminer differences for all measures except weight, which remained stable for intra- and interexaminer comparisons. These findings also suggest that weight and head circumference were the most reliable measures, whereas length and mid-arm circumference were the least reliable measures.
Authors: Marie Søfteland Sandvei; Pagona Lagiou; Pål Richard Romundstad; Dimitrios Trichopoulos; Lars Johan Vatten Journal: Eur J Epidemiol Date: 2015-05-31 Impact factor: 8.082
Authors: Sarah J Pugh; Ana M Ortega-Villa; William Grobman; Stefanie N Hinkle; Roger B Newman; Mary Hediger; Jagteshwar Grewal; Deborah A Wing; Paul S Albert; Katherine L Grantz Journal: Public Health Nutr Date: 2019-02-11 Impact factor: 4.022
Authors: Erin S Ross; Nancy F Krebs; A Laurie W Shroyer; L Miriam Dickinson; Paul H Barrett; Susan L Johnson Journal: Early Hum Dev Date: 2009-07-15 Impact factor: 2.079
Authors: Irene E Olsen; M Louise Lawson; Jareen Meinzen-Derr; Amy L Sapsford; Kurt R Schibler; Edward F Donovan; Ardythe L Morrow Journal: J Pediatr Date: 2008-11-28 Impact factor: 4.406
Authors: Fenfang Li; Lynne R Wilkens; Rachel Novotny; Marie K Fialkowski; Yvette C Paulino; Randall Nelson; Andrea Bersamin; Ursula Martin; Jonathan Deenik; Carol J Boushey Journal: Am J Hum Biol Date: 2015-10-12 Impact factor: 1.937
Authors: Melissa M Smarr; Germaine M Buck Louis; Paul S Albert; Sungduk Kim; Karin M Fuchs; Jagteshwar Grewal; Mary E D'Alton; Katherine L Grantz Journal: Am J Perinatol Date: 2017-11-30 Impact factor: 1.862
Authors: S J Pugh; A M Ortega-Villa; W Grobman; R B Newman; J Owen; D A Wing; P S Albert; K L Grantz Journal: BJOG Date: 2018-04-15 Impact factor: 6.531