X-ray imaging with amorphous selenium: optimal spectra for digital mammography.

R Fahrig1, J A Rowlands, M J Yaffe.   

Abstract

The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. The investigation is based on a model of the breast previously developed for a phosphor-based digital readout system, and has been extended to include the effects specific to the use of photoconductors. The effects of plate thickness, x-ray scatter, readout noise, dose, and the kind of breast tissue on the nature of the optimum spectrum are explored for the two readout methods. The results indicate that use of a kilovoltage setting in the current mammographic range, and a molybdenum target spectrum is appropriate for digital readout of a-Se detectors. This conclusion contrasts with the appreciably higher kilovoltages traditionally used with the xerographic (toner) readout of latent charge images on a-Se.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9157270     DOI: 10.1118/1.597688

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Modulator design for x-ray scatter correction using primary modulation: material selection.

Authors:  Hewei Gao; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

Review 2.  Digital detectors for mammography: the technical challenges.

Authors:  A Noel; F Thibault
Journal:  Eur Radiol       Date:  2004-10-08       Impact factor: 5.315

3.  Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system.

Authors:  Paula Toroi; Federica Zanca; Kenneth C Young; Chantal van Ongeval; Guy Marchal; Hilde Bosmans
Journal:  Eur Radiol       Date:  2007-02-01       Impact factor: 5.315

4.  Towards standardization of x-ray beam filters in digital mammography and digital breast tomosynthesis: Monte Carlo simulations and analytical modelling.

Authors:  Suman Shrestha; Srinivasan Vedantham; Andrew Karellas
Journal:  Phys Med Biol       Date:  2017-01-11       Impact factor: 3.609

5.  Dose comparison between screen/film and full-field digital mammography.

Authors:  Gisella Gennaro; Cosimo di Maggio
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 7.034

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.