Literature DB >> 9154868

Pressure-volume curves in acute respiratory failure: automated low flow inflation versus occlusion.

G Servillo1, C Svantesson, L Beydon, E Roupie, L Brochard, F Lemaire, B Jonson.   

Abstract

Pressure-volume (P-V) curves of the respiratory system allow determination of compliance and lower and upper inflection points (LIP and UIP, respectively). To minimize lung trauma in mechanical ventilation the tidal volume should be limited to the P-V range between LIP and UIP. An automated low flow inflation (ALFI) technique, using a computer-controlled Servo Ventilator 900C, was compared with a more conventional technique using a series of about 20 different inflated volumes (Pst-V curve). The pressure in the distal lung (Pdist) was calculated by subtraction of resistive pressure drop in connecting tubes and airways. Compliance (Cdist), Pdist(LIP), and Pdist(UIP) were derived from the Pdist-V curve and compared with Cst, Pst(LIP), and Pst(UIP) derived from the Pst-V curve. Nineteen sedated, paralyzed patients (10 with ARDS and 9 with ARF) were studied. We found: Cdist = 2.3 + 0.98 x Cst ml/cm H2O (r = 0.98); Pdist(LIP) = 0.013 + 1.09 x Pst(LIP) cm H2O (r = 0.96). In patients with ARDS: Pdist(UIP) = 4.71 + 0.84 x Pst(UIP) cm H2O (r = 0.94). In ARF, we found differences in UIP between the methods, but discrepancies occurred above tidal volumes and had little practical importance. They may reflect that Pdist comprises dynamic phenomena contributing to pressure in the distal lung at large volumes. Compliance, but not LIP and UIP, could be accurately determined without subtraction of resistive pressure from the pressure measured in the ventilator. We conclude that ALFI, which is fully automated and needing no ventilator disconnection, gives useful clinical information.

Entities:  

Mesh:

Year:  1997        PMID: 9154868     DOI: 10.1164/ajrccm.155.5.9154868

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  18 in total

1.  Elastic pressure-volume curves: what information do they convey?

Authors:  B Jonson; C Svantesson
Journal:  Thorax       Date:  1999-01       Impact factor: 9.139

2.  A single computer-controlled mechanical insufflation allows determination of the pressure-volume relationship of the respiratory system.

Authors:  C Svantesson; B Drefeldt; S Sigurdsson; A Larsson; L Brochard; B Jonson
Journal:  J Clin Monit Comput       Date:  1999-01       Impact factor: 2.502

3.  Early patterns of static pressure-volume loops in ARDS and their relations with PEEP-induced recruitment.

Authors:  Antoine Vieillard-Baron; Sebastien Prin; Karim Chergui; Bernard Page; Alain Beauchet; François Jardin
Journal:  Intensive Care Med       Date:  2003-08-16       Impact factor: 17.440

4.  Dynamic elastic pressure-volume loops in healthy pigs recorded with inspiratory and expiratory sinusoidal flow modulation. Relationship to static pressure-volume loops.

Authors:  Ulrika Bitzén; Björn Drefeldt; Lisbet Niklason; Björn Jonson
Journal:  Intensive Care Med       Date:  2004-02-13       Impact factor: 17.440

5.  Elastic pressure-volume curves in acute lung injury and acute respiratory distress syndrome.

Authors:  Björn Jonson
Journal:  Intensive Care Med       Date:  2004-12-17       Impact factor: 17.440

6.  Repeated generation of the pulmonary pressure-volume curve may lead to derecruitment in experimental lung injury.

Authors:  Dietrich Henzler; Andreas Mahnken; Rolf Dembinski; Britta Waskowiak; Rolf Rossaint; Ralf Kuhlen
Journal:  Intensive Care Med       Date:  2004-12-09       Impact factor: 17.440

7.  ICASP: an intensive-care acquisition and signal processing integrated framework.

Authors:  Eleftheria J Siachalou; Ilias K Kitsas; Konstantinos J Panoulas; Emmanouil Th Zadelis; Christos D Saragiotis; Yannis A Tolias; Leontios J Hadjileontiadis; Stavros M Panas
Journal:  J Med Syst       Date:  2005-12       Impact factor: 4.460

8.  The "open lung" compromise.

Authors:  John J Marini
Journal:  Intensive Care Med       Date:  2007-05-25       Impact factor: 17.440

9.  The semi-seated position slightly reduces the effort to breathe during difficult weaning.

Authors:  N Deye; F Lellouche; S M Maggiore; S Taillé; A Demoule; E L'Her; F Galia; A Harf; J Mancebo; L Brochard
Journal:  Intensive Care Med       Date:  2012-10-24       Impact factor: 17.440

10.  A new automated method versus continuous positive airway pressure method for measuring pressure-volume curves in patients with acute lung injury.

Authors:  Enrique Piacentini; Marc Wysocki; Lluis Blanch
Journal:  Intensive Care Med       Date:  2008-10-14       Impact factor: 17.440