Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference.

A D Milne1, D G Chess, J A Johnson, G J King.   

Abstract

The positional and rotational accuracy of a direct-current magnetic tracking device commonly used in biomechanical investigations was evaluated. The effect of different metals was also studied to determine the possibility of interference induced by experimental test fixtures or orthopaedic implants within the working field. Positional and rotational data were evaluated for accuracy and resolution by comparing the device output to known motions as derived from a calibrated grid board or materials testing machine. The effect of different metals was evaluated by placing cylindrical metal samples at set locations throughout the working field and comparing the device readings before and after introducing each metal sample. Positional testing revealed an optimal operational range with the transmitter and receiver separation between 22.5 and 64.0 cm. Within this range the mean positional error was found to be 1.8 percent of the step size, and resolution was determined to be 0.25 mm. The mean rotational error over a 1-20 degree range was found to be 1.6% of the rotational increment with a rotational resolution of 0.1 degrees. Of the metal alloys tested only mild steel produced significant interference, which was maximum when the sample was placed adjacent to the receiver. At this location the mild steel induced a positional difference of 5.26 cm and an angular difference of 9.75 degrees. The device was found to be insensitive to commonly used orthopaedic alloys. In this study, the electromagnetic tracking device was found to have positional and rotational errors of less than 2 percent, when utilized within its optimal operating range. This accuracy combined with its insensitivity to orthopaedic alloys should make it suitable for a variety of musculoskeletal research investigations.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9147976     DOI: 10.1016/0021-9290(96)83335-5

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  34 in total

Review 1.  Current opinion on computer-aided surgical navigation and robotics: role in the treatment of sports-related injuries.

Authors:  Volker Musahl; Anton Plakseychuk; Freddie H Fu
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Evaluation of a simulated pivot shift test: a biomechanical study.

Authors:  Lars Engebretsen; Coen A Wijdicks; Colin J Anderson; Benjamin Westerhaus; Robert F LaPrade
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

3.  Quantitative comparison of the pivot shift test results before and after anterior cruciate ligament reconstruction by using the three-dimensional electromagnetic measurement system.

Authors:  Kanto Nagai; Yuichi Hoshino; Yuichiro Nishizawa; Daisuke Araki; Takehiko Matsushita; Tomoyuki Matsumoto; Koji Takayama; Kouki Nagamune; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-05       Impact factor: 4.342

Review 4.  Collecting shoulder kinematics with electromagnetic tracking systems and digital inclinometers: A review.

Authors:  Daniel C Hannah; Jason S Scibek
Journal:  World J Orthop       Date:  2015-11-18

5.  The effect of graft tensioning in anatomic 2-bundle ACL reconstruction on knee joint kinematics.

Authors:  Yuichi Hoshino; Ryosuke Kuroda; Kouki Nagamune; Koji Nishimoto; Masayoshi Yagi; Kiyonori Mizuno; Shinichi Yoshiya; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-12-23       Impact factor: 4.342

6.  Analysis of the graft bending angle at the femoral tunnel aperture in anatomic double bundle anterior cruciate ligament reconstruction: a comparison of the transtibial and the far anteromedial portal technique.

Authors:  Koji Nishimoto; Ryosuke Kuroda; Kiyonori Mizuno; Yuichi Hoshino; Kouki Nagamune; Seiji Kubo; Masayoshi Yagi; Motoi Yamaguchi; Shinichi Yoshiya; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-02       Impact factor: 4.342

7.  The effect of intra-operative knee flexion angle on determination of graft location in the anatomic double-bundle anterior cruciate ligament reconstruction.

Authors:  Yuichi Hoshino; Kouki Nagamune; Masayoshi Yagi; Daisuke Araki; Koji Nishimoto; Seiji Kubo; Doita Minoru; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-21       Impact factor: 4.342

8.  Intraoperative monitoring of laparoscopic skill development based on quantitative measures.

Authors:  Sayra M Cristancho; Antony J Hodgson; O N M Panton; Adam Meneghetti; Garth Warnock; Karim Qayumi
Journal:  Surg Endosc       Date:  2008-12-31       Impact factor: 4.584

9.  Greater fear of reinjury is related to stiffened jump-landing biomechanics and muscle activation in women after ACL reconstruction.

Authors:  Stephanie M Trigsted; Dane B Cook; Kristen A Pickett; Lisa Cadmus-Bertram; Warren R Dunn; David R Bell
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-26       Impact factor: 4.342

10.  Verification of fetal brain responses by coregistration of fetal ultrasound and fetal magnetoencephalography data.

Authors:  C Micheli; J McCubbin; P Murphy; H Eswaran; C L Lowery; E Ortiz; H Preissl
Journal:  Neuroimage       Date:  2009-09-22       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.