Literature DB >> 9147602

Analysis of correlated ROC areas in diagnostic testing.

H H Song1.   

Abstract

This paper focuses on methods of analysis of areas under receiver operating characteristic (ROC) curves. Analysis of ROC areas should incorporate the correlation structure of repeated measurements taken on the same set of cases and the paucity of measurements per treatment resulting from an effective summarization of cases into a few area measures of diagnostic accuracy. The repeated nature of ROC data has been taken into consideration in the analysis methods previously suggested by Swets and Pickett (1982, Evaluation of Diagnostic Systems: Methods from Signal Detection Theory), Hanley and McNeil (1983, Radiology 148, 839-843), and DeLong, DeLong, and Clarke-Pearson (1988, Biometrics 44, 837-845). DeLong et al.'s procedure is extended to a Wald test for general situations of diagnostic testing. The method of analyzing jackknife pseudovalues by treating them as data is extremely useful when the number of area measures to be tested is quite small. The Wald test based on covariances of multivariate multisample U-statistics is compared with two approaches of analyzing pseudovalues, the univariate mixed-model analysis of variance (ANOVA) for repeated measurements and the three-way factorial ANOVA. Monte Carlo simulations demonstrate that the three tests give good approximation to the nominal size at the 5% levels for large sample sizes, but the paired t-test using ROC areas as data lacks the power of the other three tests and Hanley and McNeil's method is inappropriate for testing diagnostic accuracies. The Wald statistic performs better than the ANOVAs of pseudovalues. Jackknifing schemes of multiple deletion where different structures of normal and diseased distributions are accounted for appear to perform slightly better than simple multiple-deletion schemes but no appreciable power difference is apparent, and deletion of too many cases at a time may sacrifice power. These methods have important applications in diagnostic testing in ROC studies of radiology and of medicine in general.

Entities:  

Mesh:

Year:  1997        PMID: 9147602

Source DB:  PubMed          Journal:  Biometrics        ISSN: 0006-341X            Impact factor:   2.571


  13 in total

1.  A nonparametric procedure for comparing the areas under correlated LROC curves.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Med Imaging       Date:  2012-06-18       Impact factor: 10.048

2.  Is optical coherence tomography an effective device for evaluation of tear film meniscus in patients with acne rosacea?

Authors:  F C Eroglu; A Karalezli; R Dursun
Journal:  Eye (Lond)       Date:  2016-01-15       Impact factor: 3.775

3.  Automated early detection of diabetic retinopathy.

Authors:  Michael D Abràmoff; Joseph M Reinhardt; Stephen R Russell; James C Folk; Vinit B Mahajan; Meindert Niemeijer; Gwénolé Quellec
Journal:  Ophthalmology       Date:  2010-06       Impact factor: 12.079

4.  Power calculation for comparing diagnostic accuracies in a multi-reader, multi-test design.

Authors:  Eunhee Kim; Zheng Zhang; Youdan Wang; Donglin Zeng
Journal:  Biometrics       Date:  2014-10-29       Impact factor: 2.571

5.  Long term ultrasonic follow up of choroidal naevi and their transformation to melanomas.

Authors:  I Kaiserman; N Kaiserman; J Pe'er
Journal:  Br J Ophthalmol       Date:  2006-05-03       Impact factor: 4.638

6.  Can serum hyaluronic acid replace simple non-invasive indexes to predict liver fibrosis in HIV/Hepatitis C coinfected patients?

Authors:  Salvador Resino; José M Bellón; Cristina Asensio; Dariela Micheloud; Pilar Miralles; Ana Vargas; Pilar Catalán; Juan C López; Emilio Alvarez; Jaime Cosin; Raquel Lorente; María A Muñoz-Fernández; Juan Berenguer
Journal:  BMC Infect Dis       Date:  2010-08-19       Impact factor: 3.090

7.  Comparison of serum cystatin C, serum creatinine, measured GFR, and estimated GFR to assess the risk of kidney failure in American Indians with diabetic nephropathy.

Authors:  Meda E Pavkov; William C Knowler; Robert L Hanson; Desmond E Williams; Kevin V Lemley; Bryan D Myers; Robert G Nelson
Journal:  Am J Kidney Dis       Date:  2013-01-21       Impact factor: 8.860

8.  PSA doubling time versus PSA velocity to predict high-risk prostate cancer: data from the Baltimore Longitudinal Study of Aging.

Authors:  Stacy Loeb; Anna Kettermann; Luigi Ferrucci; Patricia Landis; E Jeffrey Metter; H Ballentine Carter
Journal:  Eur Urol       Date:  2008-07-02       Impact factor: 20.096

9.  Predictive power of sequential measures of albuminuria for progression to ESRD or death in Pima Indians with type 2 diabetes.

Authors:  Meda E Pavkov; William C Knowler; Robert L Hanson; Peter H Bennett; Robert G Nelson
Journal:  Am J Kidney Dis       Date:  2008-03-20       Impact factor: 8.860

10.  Value of three dimensional power Doppler ultrasound in prediction of endometrial carcinoma in patients with postmenopausal bleeding.

Authors:  Sherif Hanafi; Ahmed Abou-Gabal; Sherif Akl; Heba Abd El Baset
Journal:  J Turk Ger Gynecol Assoc       Date:  2014-06-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.