Literature DB >> 9144671

Dynamic contrast-enhanced T2*-weighted MRI in patients with cerebrovascular disease.

W Reith1, S Heiland, G Erb, T Benner, M Forsting, K Sartor.   

Abstract

Our purpose was to investigate the potential of dynamic susceptibility contrast-enhanced MRI in assessing regional haemodynamics in patients with cerebrovascular disease. T2*-weighted FLASH sequences were performed on a control group of 10 healthy subjects, 13 patients with unilateral stenosis or occlusion of the internal carotid artery and 6 patients with acute onset of neurological symptoms, the observed signal intensities being converted into concentration-time curves. A gamma-variate function was fitted to the measured concentration-time curves to eliminate effects of tracer recirculation. In each patient the two cerebral hemispheres were compared and the difference between the mean transit times and the percental change of the regional cerebral blood volume, calculated for each side. Patients with haemodynamically significant unilateral carotid obstruction can be divided into two subgroups: those with good and those with poor collateral supply. Patients with good collateral supply had a slight but not statistically significant increase in mean transit time and cerebral blood volume on the diseased side, whereas those with poor collaterals had a significant increase compared with the control group. In patients with acute onset of neurological symptoms perfusion maps clearly demonstrated the disturbed perfusion at a time when T2-weighted images were still normal. Perfusion imaging is a reliable and noninvasive method of assessing changes in cerebral perfusion in patients with unilateral carotid stenosis. This MR technique permits monitoring of haemodynamic changes during therapy and thus may become an alternative to SPECT and PET scanning. In patients with acute occlusion of a cerebral artery, perfusion imaging reveals the entire, perfusion deficit before conventional MRI and thus allows early intervention.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9144671     DOI: 10.1007/s002340050403

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  3 in total

1.  Evaluation of flow measurement from the first pass bolus T1 weighted images using inversion recovery sequence.

Authors:  M Nazarpoor
Journal:  Br J Radiol       Date:  2010-10-19       Impact factor: 3.039

2.  Dynamic spin labeling angiography in extracranial carotid artery stenosis.

Authors:  Carsten Warmuth; Maria Rüping; Annette Förschler; Hans-Christian Koennecke; Jose Manuel Valdueza; Andreas Kauert; Stephan J Schreiber; Ralf Siekmann; Claus Zimmer
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

3.  Cerebral perfusion in infants and neonates: preliminary results obtained using dynamic susceptibility contrast enhanced magnetic resonance imaging.

Authors:  S F Tanner; L Cornette; L A Ramenghi; L S Miall; J P Ridgway; M A Smith; M I Levene
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-11       Impact factor: 5.747

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.