Literature DB >> 9143462

Bayesian image reconstruction for emission tomography based on median root prior.

S Alenius1, U Ruotsalainen.   

Abstract

The aim of the present study was to investigate a new type of Bayesian one-step late reconstruction method which utilizes a median root prior (MRP). The method favours images which have locally monotonous radioactivity concentrations. The new reconstruction algorithm was applied to ideal simulated data, phantom data and some patient examinations with PET. The same projection data were reconstructed with filtered back-projection (FBP) and maximum likelihood-expectation maximization (ML-EM) methods for comparison. The MRP method provided good-quality images with a similar resolution to the FBP method with a ramp filter, and at the same time the noise properties were as good as with Hann-filtered FBP images. The typical artefacts seen in FBP reconstructed images outside of the object were completely removed, as was the grainy noise inside the object. Quantitatively, the resulting average regional radioactivity concentrations in a large region of interest in images produced by the MRP method corresponded to the FBP and ML-EM results but at the pixel by pixel level the MRP method proved to be the most accurate of the tested methods. In contrast to other iterative reconstruction methods, e.g. ML-EM, the MRP method was not sensitive to the number of iterations nor to the adjustment of reconstruction parameters. Only the Bayesian parameter beta had to be set. The proposed MRP method is much more simple to calculate than the methods described previously, both with regard to the parameter settings and in terms of general use. The new MRP reconstruction method was shown to produce high-quality quantitative emission images with only one parameter setting in addition to the number of iterations.

Entities:  

Mesh:

Year:  1997        PMID: 9143462     DOI: 10.1007/bf01728761

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  42 in total

1.  Exercise training improves insulin-stimulated myocardial glucose uptake in patients with dilated cardiomyopathy.

Authors:  Kira Q Stolen; Jukka Kemppainen; Kari K Kalliokoski; Matti Luotolahti; Tapio Viljanen; Pirjo Nuutila; Juhani Knuuti
Journal:  J Nucl Cardiol       Date:  2003 Sep-Oct       Impact factor: 5.952

2.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

3.  Improved quantification in multiple-pinhole SPECT by anatomy-based reconstruction using microCT information.

Authors:  Christian Vanhove; Michel Defrise; Axel Bossuyt; Tony Lahoutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-09-30       Impact factor: 9.236

4.  Intact insulin stimulation of skeletal muscle blood flow, its heterogeneity and redistribution, but not of glucose uptake in non-insulin-dependent diabetes mellitus.

Authors:  T Utriainen; P Nuutila; T Takala; P Vicini; U Ruotsalainen; T Rönnemaa; T Tolvanen; M Raitakari; M Haaparanta; O Kirvelä; C Cobelli; H Yki-Järvinen
Journal:  J Clin Invest       Date:  1997-08-15       Impact factor: 14.808

Review 5.  Advances in technical aspects of myocardial perfusion SPECT imaging.

Authors:  Piotr J Slomka; James A Patton; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2009-02-26       Impact factor: 5.952

6.  Non-invasive diagnosis of acute mesenteric ischaemia using PET.

Authors:  Jan Kiss; Alexandru Naum; Nobuyuki Kudomi; Juhani Knuuti; Patricia Iozzo; Timo Savunen; Pirjo Nuutila
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03-11       Impact factor: 9.236

7.  Non-invasive estimation of hepatic blood perfusion from H2 15O PET images using tissue-derived arterial and portal input functions.

Authors:  N Kudomi; L Slimani; M J Järvisalo; J Kiss; R Lautamäki; G A Naum; T Savunen; J Knuuti; H Iida; P Nuutila; P Iozzo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-05-06       Impact factor: 9.236

8.  Myocardial and skeletal muscle glucose uptake during exercise in humans.

Authors:  Jukka Kemppainen; Toshihiko Fujimoto; Kari K Kalliokoski; Tapio Viljanen; Pirjo Nuutila; Juhani Knuuti
Journal:  J Physiol       Date:  2002-07-15       Impact factor: 5.182

9.  Assessment of right ventricular oxidative metabolism by PET in patients with idiopathic dilated cardiomyopathy undergoing cardiac resynchronization therapy.

Authors:  Juhani Knuuti; Jan Sundell; Alexandru Naum; Erik Engblom; Juhani Koistinen; Antti Ylitalo; Kira Q Stolen; Riikka Kalliokoski; Stephan G Nekolla; K E Jeroen J Bax; K E Juhani Airaksinen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-07-29       Impact factor: 9.236

10.  Diabetic background retinopathy is associated with impaired coronary vasoreactivity in people with Type 1 diabetes.

Authors:  J Sundell; T Janatuinen; T Rönnemaa; O T Raitakari; J Toikka; P Nuutila; J Knuuti
Journal:  Diabetologia       Date:  2004-04       Impact factor: 10.122

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.