BACKGROUND: For evaluating pancreaticobiliary stenoses during endoscopic retrograde cholangiopancreatography (ERCP) tissue sampling techniques may be important. Brush cytology and forceps biopsy during ERCP are two potential, but so far only incompletely evaluated, tools for the diagnosis of malignant biliary or pancreatic stenoses. METHODS: Between 1992 and 1995 we acquired 133 cytologic and/or histologic samples from 119 patients who underwent ERCP because of biliary duct stenoses. Sixteen patients had to be excluded from the study due to insufficient follow-up information. After papillotomy, brush cytology was performed in 65 cases (63 patients), and forceps biopsy in 119 cases (106 patients under fluoroscopic guidance. Both methods were applied in combination 51 times (48 patients). The nature of the stenoses was confirmed by surgery, autopsy, or by the subsequent clinical course. RESULTS: The sensitivity was 46.7% for brush cytology and 64.9% for forceps biopsy. The combined application of both methods resulted in superior sensitivity (70.4%). Specificity was 100% for all methods. CONCLUSIONS: These numbers lead us to recommend a combined and more frequent application of brush cytology and forceps biopsy of bile duct stenoses to enhance the diagnostic yield whenever substantial influence on therapy can be expected.
BACKGROUND: For evaluating pancreaticobiliary stenoses during endoscopic retrograde cholangiopancreatography (ERCP) tissue sampling techniques may be important. Brush cytology and forceps biopsy during ERCP are two potential, but so far only incompletely evaluated, tools for the diagnosis of malignant biliary or pancreatic stenoses. METHODS: Between 1992 and 1995 we acquired 133 cytologic and/or histologic samples from 119 patients who underwent ERCP because of biliary duct stenoses. Sixteen patients had to be excluded from the study due to insufficient follow-up information. After papillotomy, brush cytology was performed in 65 cases (63 patients), and forceps biopsy in 119 cases (106 patients under fluoroscopic guidance. Both methods were applied in combination 51 times (48 patients). The nature of the stenoses was confirmed by surgery, autopsy, or by the subsequent clinical course. RESULTS: The sensitivity was 46.7% for brush cytology and 64.9% for forceps biopsy. The combined application of both methods resulted in superior sensitivity (70.4%). Specificity was 100% for all methods. CONCLUSIONS: These numbers lead us to recommend a combined and more frequent application of brush cytology and forceps biopsy of bile duct stenoses to enhance the diagnostic yield whenever substantial influence on therapy can be expected.
Authors: Helmut Witzigmann; Frieder Berr; Ulrike Ringel; Karel Caca; Dirk Uhlmann; Konrad Schoppmeyer; Andrea Tannapfel; Christian Wittekind; Joachim Mossner; Johann Hauss; Marcus Wiedmann Journal: Ann Surg Date: 2006-08 Impact factor: 12.969
Authors: Kenneth K Wang; David L Carr-Locke; Satish K Singh; Helmut Neumann; Helga Bertani; Jean-Paul Galmiche; Razvan I Arsenescu; Fabrice Caillol; Kenneth J Chang; Stanislas Chaussade; Emmanuel Coron; Guido Costamagna; Aldona Dlugosz; S Ian Gan; Marc Giovannini; Frank G Gress; Oleh Haluszka; Khek Y Ho; Michel Kahaleh; Vani J Konda; Frederic Prat; Raj J Shah; Prateek Sharma; Adam Slivka; Herbert C Wolfsen; Alvin Zfass Journal: United European Gastroenterol J Date: 2015-06 Impact factor: 4.623