Literature DB >> 9135663

Accuracy of volume measurement using helical CT.

S Nawaratne1, R Fabiny, J E Brien, J Zalcberg, W Cosolo, A Whan, D J Morgan.   

Abstract

PURPOSE: Our goal was to determine the accuracy of volume estimation using helical CT.
METHOD: Helical CT scans were conducted with regularly and irregularly shaped polyvinylchloride bags containing saline of varying volumes immersed in peanut oil during various rates of movement of 0, 10, 15, and 20 cycles/min, using a motorized platform, designed to simulate respiratory motion. Ten cancer patients were scanned with CT to determine optimum upper and lower Hounsfield unit thresholds. The volumes of two human livers and kidneys were also measured in vitro under the same conditions.
RESULTS: For all conditions, the accuracy and bias of volume estimation for saline bags ranged from 95.0 to 99.2 and -3.46 to 4.04%, respectively, and the accuracy and bias for the estimation of liver and kidney volumes were 95.6 and 3.12%, respectively.
CONCLUSION: This study shows that helical CT is a highly accurate technique for estimating volume, even in the presence of simulated respiratory motion.

Entities:  

Mesh:

Year:  1997        PMID: 9135663     DOI: 10.1097/00004728-199705000-00027

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  12 in total

1.  Hepatic height on coronal computed tomography images predicts total liver volume in European adults without liver disease.

Authors:  Philippe Soyer; Marc Sirol; Anthony Dohan; Etienne Gayat; Vinciane Placé; Lora Hristova; Lounis Hamzi; Mourad Boudiaf
Journal:  Dig Dis Sci       Date:  2012-06       Impact factor: 3.199

2.  Relationships among liver and kidney volumes, lean body mass and drug clearance.

Authors:  S Nawaratne; J E Brien; E Seeman; R Fabiny; J Zalcberg; W Cosolo; P Angus; D J Morgan
Journal:  Br J Clin Pharmacol       Date:  1998-11       Impact factor: 4.335

3.  The estimation of the volume of sheep mandibular defects using cone-beam computed tomography images and a stereological method.

Authors:  S Kayipmaz; O S Sezgin; S T Saricaoglu; O Bas; B Sahin; M Küçük
Journal:  Dentomaxillofac Radiol       Date:  2011-03       Impact factor: 2.419

4.  Feasibility of using CT volume as a predictor of specimen weight in a subgroup of patients with low risk Wilms tumors registered on COG Study AREN03B2: implications for central venous catheter placement.

Authors:  Fernando A Ferrer; Katherine W Herbst; Conrad V Fernandez; Geetika Khanna; Jeffrey S Dome; Arlene Naranjo; Elizabeth A Mullen; James I Geller; Eric J Gratias; Robert Shamberger; Michael Ritchey; Peter F Ehrlich
Journal:  J Pediatr Urol       Date:  2014-03-15       Impact factor: 1.830

5.  Renal volume assessment with 3D ultrasound.

Authors:  A Brancaforte; S Serantoni; F Silva Barbosa; G Di Leo; F Sardanelli; G P Cornalba
Journal:  Radiol Med       Date:  2011-06-04       Impact factor: 3.469

6.  Liver and spleen volume variations in patients with hepatic fibrosis.

Authors:  Peng Liu; Peng Li; Wen He; Li-Qin Zhao
Journal:  World J Gastroenterol       Date:  2009-07-14       Impact factor: 5.742

7.  Validation of multi-detector computed tomography as a non-invasive method for measuring ovarian volume in macaques (Macaca fascicularis).

Authors:  Jeryl C Jones; Susan E Appt; Stephen R Werre; Joshua C Tan; Jay R Kaplan
Journal:  Am J Primatol       Date:  2010-06       Impact factor: 2.371

8.  Tumor volume as determined by computed tomography predicts local control in hypopharyngeal squamous cell carcinoma treated with primary surgery.

Authors:  Marc Keberle; Florian Hoppe; Silke Dotzel; Dietbert Hahn
Journal:  Eur Radiol       Date:  2003-07-05       Impact factor: 5.315

9.  Pancreas volumes in humans from birth to age one hundred taking into account sex, obesity, and presence of type-2 diabetes.

Authors:  Y Saisho; A E Butler; J J Meier; T Monchamp; M Allen-Auerbach; R A Rizza; P C Butler
Journal:  Clin Anat       Date:  2007-11       Impact factor: 2.414

10.  Measurement by multidetector CT scan of the volume of hypopharyngeal and laryngeal tumours: accuracy and reproducibility.

Authors:  Lorenzo Preda; Elena Lovati; Fausto Chiesa; Mohssen Ansarin; Laura Cattaneo; Roberta Fasani; Sara Gandini; Nicola Flor; Gianpaolo Cornalba; Massimo Bellomi
Journal:  Eur Radiol       Date:  2007-02-14       Impact factor: 7.034

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.