A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing.

V DeCaprio, P Hurzeler, S Furman.   

Abstract

Simultaneous unipolar and bipolar electrograms were recorded and compared from 49 pacemaker patients with bipolar endocardial electrodes. Average bipolar depolarization signal voltage equalled that of unipolar but showed greater variation. Bipolar and unipolar slew rates were equal in both mean and variance. The proximal pole voltage had little effect on the bipolar result in 8% of the cases, tended to cancel the tip voltage in 49% of the cases and augmented the tip voltage in 43% of the electrograms. The average bipolar R wave duration was 28% less, the T wave amplitude 34% less, and the ST-segment elevation 37% less than the unipolar values. By consistently attenuating the undersirable T waves and ST elevations, while leaving the depolarization signal unaffected, the bipolar electrode offered the advantage of a superior signal-to-noise ratio for sensing depolarization. In one case, however, the bipolar signal was so small as to cause a clinical sensing failure.

Entities:  

Mesh:

Year:  1977        PMID: 912833     DOI: 10.1161/01.cir.56.5.750

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  8 in total

1.  Mechanism and magnitude of bipolar electrogram directional sensitivity: Characterizing underlying determinants of bipolar amplitude.

Authors:  Stephen Gaeta; Tristram D Bahnson; Craig Henriquez
Journal:  Heart Rhythm       Date:  2019-12-13       Impact factor: 6.343

2.  Chest wall stimulator for pacemaker inhibiton.

Authors:  N Goldschlager; B Andrews
Journal:  West J Med       Date:  1983-04

3.  A novel lead configuration for optimal spatio-temporal detection of intracardiac repolarization alternans.

Authors:  Eric H Weiss; Faisal M Merchant; Andre d'Avila; Lori Foley; Vivek Y Reddy; Jagmeet P Singh; Theofanie Mela; Jeremy N Ruskin; Antonis A Armoundas
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-03-23

4.  R-wave detection by subcutaneous ECG. Possible use for analyzing R-R variability.

Authors:  P Fotuhi; W Combs; C Condie; H Theres; T Schneider; K Stangl; G Baumann
Journal:  Ann Noninvasive Electrocardiol       Date:  2001-01       Impact factor: 1.468

5.  Improved spatial resolution and electrogram wave direction independence with the use of an orthogonal electrode configuration.

Authors:  Nathaniel C Thompson; Justin Stinnett-Donnelly; Nicole Habel; Bryce Benson; Jason H T Bates; Burton E Sobel; Peter S Spector
Journal:  J Clin Monit Comput       Date:  2013-09-26       Impact factor: 2.502

6.  Comparison of unipolar and bipolar ventricular paced evoked responses.

Authors:  M W Baig; J C Cowan; E J Perrins
Journal:  Br Heart J       Date:  1992-10

7.  Suggestions to evaluate whether T-wave alternans is T-wave amplitude dependent.

Authors:  John E Madias
Journal:  Indian Pacing Electrophysiol J       Date:  2009-03-15

8.  Time course of current of injury is related to acute stability of active-fixation pacing leads in rabbits.

Authors:  Shalaimaiti Shali; Alimujiang Wushou; Entao Liu; Lin Jia; Ruiming Yao; Yangang Su; Junbo Ge
Journal:  PLoS One       Date:  2013-03-05       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.