Literature DB >> 9127309

Lens coupling efficiency: derivation and application under differing geometrical assumptions.

T Yu1, J M Boone.   

Abstract

The calculation of lens coupling efficiency is often performed in the design of lens coupled digital radiographic system, now currently under development. With these systems, an electronic camera is focused onto a planar scintillator such as a conventional intensifying screen. Historically, this calculation has relied on certain assumptions concerning the emission properties of the scintillator, and primarily this assumption is that the scintillator is either a Lambertain emitter (light is emitted over all angles equally) or a point radiator. Because there now exists new classes of scintillators such as scintillating fiber optic screens and pixelated intensifying screens, it is sometimes necessary to perform lens coupling calculations in the absence of the Lambertian and point source assumptions. In this paper we describe the necessary equations to accurately calculate lens coupling efficiency in the most general of cases. Graphical examples demonstrate the lens coupling efficiency for hypothetical Lambertain scintillating sources, for a rare earth intensifying screen, and for a scintillating fiber optical screen.

Mesh:

Year:  1997        PMID: 9127309     DOI: 10.1118/1.598055

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams.

Authors:  Sam Beddar; Louis Archambault; Narayan Sahoo; Falk Poenisch; George T Chen; Michael T Gillin; Radhe Mohan
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

2.  A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization.

Authors:  Frédéric Lacroix; A Sam Beddar; Mathieu Guillot; Luc Beaulieu; Luc Gingras
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

3.  Optically stimulated luminescence in state-of-the-art LYSO:Ce scintillators enables high spatial resolution 3D dose imaging.

Authors:  Mads L Jensen; Rosana M Turtos; Jacob S Nyemann; Ludvig P Muren; Brian Julsgaard; Peter Balling
Journal:  Sci Rep       Date:  2022-05-18       Impact factor: 4.996

4.  Cerenkov radiation imaging as a method for quantitative measurements of beta particles in a microfluidic chip.

Authors:  Jennifer S Cho; Richard Taschereau; Sebastian Olma; Kan Liu; Yi-Chun Chen; Clifton K-F Shen; R Michael van Dam; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2009-10-21       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.