Literature DB >> 9126943

Off-resonance pulsed magnetization transfer in clinical MR imaging: optimization by an analysis of transients.

J Listerud1.   

Abstract

Significant degrees of magnetization transfer (MT) have been observed in the magnetic resonance imaging of biological materials by conventional clinical imaging sequences, as well as by sequences specifically designed to enhance MT image contrast. Two aspects of these procedures distinguish them from the classic spectroscopic MT experiments using either so-called "hard" radiofrequency (RF) pulses of short duration and high power, or continuous wave RF irradiation of low power. First, clinical sequences must make exclusive use of "soft" pulses of intermediate length and power. Second, biological materials are modeled by a two-spin system involving magnetization transfer between a narrow and a broad homogeneous spectral component. Such materials are a relatively restricted group within the larger family of materials studied with MT by spectroscopy. The current paper addresses these two issues with a theory that gives a new transient analysis of the off-resonance pulsed MT problem for biological materials. It leads to predictions for optimal magnetization transfer in the context of medical imaging that have been verified by computer modeling.

Mesh:

Year:  1997        PMID: 9126943     DOI: 10.1002/mrm.1910370511

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Glioblastoma (GBM) effects on quantitative MRI of contralateral normal appearing white matter.

Authors:  Hatef Mehrabian; Wilfred W Lam; Sten Myrehaug; Arjun Sahgal; Greg J Stanisz
Journal:  J Neurooncol       Date:  2018-03-28       Impact factor: 4.130

2.  Magnetization transfer characteristics in atherosclerotic plaque components assessed by adapted binomial preparation pulses.

Authors:  M Pachot-Clouard; F Vaufrey; L Darrasse; J F Toussainti
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

3.  Simultaneous multi-angular relaxometry of tissue with MRI (SMART MRI): Theoretical background and proof of concept.

Authors:  Alexander L Sukstanskii; Jie Wen; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2016-03-15       Impact factor: 4.668

4.  A comparison between equations describing in vivo MT: the effects of noise and sequence parameters.

Authors:  Mara Cercignani; Gareth J Barker
Journal:  J Magn Reson       Date:  2007-12-25       Impact factor: 2.229

5.  Quantitative Magnetization Transfer in Monitoring Glioblastoma (GBM) Response to Therapy.

Authors:  Hatef Mehrabian; Sten Myrehaug; Hany Soliman; Arjun Sahgal; Greg J Stanisz
Journal:  Sci Rep       Date:  2018-02-06       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.