Two methods for peak RF power minimization of multiple inversion-band pulses.

G Goelman1.   

Abstract

Two novel methods to minimize peak RF power for high order longitudinal Hadamard encoding are described and demonstrated experimentally. The first method uses the fact that the choice of a reference phase in an inversion process does not affect the final frequency response. In this method, the different single inversion-band pulses are added together, each with a different reference phase. For a proper phase choice, minimization of the peak RF power is obtained. Scaling laws are defined allowing the use of a given phase-set in multiple cases. In the second method, single inversion-band pulses are added together, each partially shifted in time. This results in a significant reduction in peak power with only a moderate increase in pulse length. Theoretical conditions outlining the optimal addition order are defined. Experimental results verify the theoretical conditions and demonstrate that the frequency response is not affected by the peak power minimization process. With the new low peak RF power, longitudinal Hadamard encoding of 8TH (or 16TH) order can be performed in any clinical setting.

Entities:  

Mesh:

Year:  1997        PMID: 9126939     DOI: 10.1002/mrm.1910370506

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  Comparison of optimized soft-tissue suppression schemes for ultrashort echo time MRI.

Authors:  Cheng Li; Jeremy F Magland; Hamidreza Saligheh Rad; Hee Kwon Song; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

2.  Three-dimensional Hadamard-encoded proton spectroscopic imaging in the human brain using time-cascaded pulses at 3 Tesla.

Authors:  Ouri Cohen; Assaf Tal; Oded Gonen
Journal:  Magn Reson Med       Date:  2013-11-20       Impact factor: 4.668

3.  Root-flipped multiband refocusing pulses.

Authors:  Anuj Sharma; Michael Lustig; William A Grissom
Journal:  Magn Reson Med       Date:  2015-02-22       Impact factor: 4.668

4.  Theoretical and experimental evaluation of multi-band EPI for high-resolution whole brain pCASL Imaging.

Authors:  Xiufeng Li; Dingxin Wang; Edward J Auerbach; Steen Moeller; Kamil Ugurbil; Gregory J Metzger
Journal:  Neuroimage       Date:  2014-10-23       Impact factor: 6.556

5.  Lactate imaging with Hadamard-encoded slice-selective multiple quantum coherence chemical-shift imaging.

Authors:  Stephen Pickup; Seung-Cheol Lee; Anthony Mancuso; Jerry D Glickson
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

6.  Evaluation of slice accelerations using multiband echo planar imaging at 3 T.

Authors:  Junqian Xu; Steen Moeller; Edward J Auerbach; John Strupp; Stephen M Smith; David A Feinberg; Essa Yacoub; Kâmil Uğurbil
Journal:  Neuroimage       Date:  2013-07-27       Impact factor: 6.556

7.  Low peak power multiband spokes pulses for B1 (+) inhomogeneity-compensated simultaneous multislice excitation in high field MRI.

Authors:  Anuj Sharma; Roland Bammer; V Andrew Stenger; William A Grissom
Journal:  Magn Reson Med       Date:  2014-09-09       Impact factor: 4.668

8.  Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses.

Authors:  Edward J Auerbach; Junqian Xu; Essa Yacoub; Steen Moeller; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2013-03-06       Impact factor: 4.668

Review 9.  Rapid brain MRI acquisition techniques at ultra-high fields.

Authors:  Kawin Setsompop; David A Feinberg; Jonathan R Polimeni
Journal:  NMR Biomed       Date:  2016-02-02       Impact factor: 4.044

10.  In vivo free induction decay based 3D multivoxel longitudinal hadamard spectroscopic imaging in the human brain at 3 T.

Authors:  Assaf Tal; Gadi Goelman; Oded Gonen
Journal:  Magn Reson Med       Date:  2012-05-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.