Literature DB >> 9124976

Safe and effective method of stabilization for coronary artery bypass grafting on the beating heart.

H Shennib1, A G Lee, J Akin.   

Abstract

BACKGROUND: There is an emerging interest in performing coronary artery bypass grafting on the beating heart. This study examines the efficacy and safety of two types of coronary artery stabilizers developed to perform coronary artery bypass grafting on the beating heart.
METHODS: Four dogs underwent left internal mammary artery to left anterior descending artery anastomosis using a retractor-fixed stabilizer. Measurements of hemodynamic indices and range of motion of the targeted arteriotomy were done before and after application of the stabilizers. Patency of the anastomosis was evaluated by angiography. To clinically validate the safety of this stabilizer, we collected data on 150 patients from centers that had access to the retractor-fixed stabilizer.
RESULTS: All animals survived the procedure with no ischemic changes or hemodynamic alterations. A significant reduction in range of motion (mm) of the left anterior descending coronary artery was achieved after application of the stabilizers. Angiographic studies showed good anastomotic patency. Histologic examination showed no myocardial injury. Patient data revealed successful completion of the anastomosis, with conversion to sternotomy or cardiopulmonary bypass in 1 patient each. Intraoperative and postoperative myocardial infarctions occurred in 1 patient each, with one in-hospital death.
CONCLUSIONS: Significant stabilization of targeted coronary arteries allowing the performance of safe and reliable anastomosis on a beating heart can be achieved using the stabilizer.

Entities:  

Mesh:

Year:  1997        PMID: 9124976     DOI: 10.1016/s0003-4975(97)00010-6

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

1.  Combined coronary artery and abdominal aortic surgery without cardiopulmonary bypass.

Authors:  R Ascione; G Iannelli; N Spampinato
Journal:  Tex Heart Inst J       Date:  2000

2.  Local cardiac wall stabilization influences the reproducibility of regional wall motion during off-pump coronary artery pass surgery.

Authors:  T Shiga; K Terajima; J Matsumura; A Sakamoto; R Ogawa
Journal:  J Clin Monit Comput       Date:  2000-01       Impact factor: 2.502

3.  Toward totally endoscopic coronary artery surgery.

Authors:  R H J Trimlett; A C De Souza; A S Coonar; K M Jurgens; R Kuenzler; J R Pepper
Journal:  Surg Endosc       Date:  2003-12-29       Impact factor: 4.584

4.  On-pump with beating heart or cardioplegic arrest for emergency conversion to cardiopulmonary bypass during off-pump coronary artery bypass.

Authors:  Lei Yu; Tianxiang Gu; Enyi Shi; Chun Wang; Qin Fang; Yuhai Zhang; Chunmao Lu
Journal:  Ann Saudi Med       Date:  2014 Jul-Aug       Impact factor: 1.526

5.  Myocardial protection and early outcome of different coronary surgical techniques for diabetic patients with triple vessels.

Authors:  Yu Lei; Tianxiang Gu; Enyi Shi; Chun Wang; Fang Qin
Journal:  Ann Saudi Med       Date:  2014 Sep-Oct       Impact factor: 1.526

6.  Off-pump versus on-pump coronary artery bypass surgery in patients with triple-vessel disease and enlarged ventricles.

Authors:  Lei Yu; Tianxiang Gu; Enyi Shi; Chun Wang; Qin Fang; Yang Yu; Xiaoqi Zhao; Cheng Qian
Journal:  Ann Saudi Med       Date:  2014 May-Jun       Impact factor: 1.526

7.  Mid-term outcomes of off-pump versus on-pump coronary artery bypass graft surgery; statistical challenges in comparison.

Authors:  Ali Sheikhy; Aida Fallahzadeh; Saeed Sadeghian; Khalil Forouzannia; Jamshid Bagheri; Abbas Salehi-Omran; Masih Tajdini; Arash Jalali; Mina Pashang; Kaveh Hosseini
Journal:  BMC Cardiovasc Disord       Date:  2021-08-28       Impact factor: 2.298

  7 in total