Literature DB >> 9114600

Excess soluble urokinase-type plasminogen activator receptor in the plasma of patients with paroxysmal nocturnal hemoglobinuria inhibits cell-associated fibrinolytic activity.

H Ninomiya1, Y Hasegawa, T Nagasawa, T Abe.   

Abstract

The plasma levels of soluble urokinase-type plasminogen activator receptor (uPAR; CD87) measured by enzyme-linked immunosorbent assay were higher in patients with paroxysmal nocturnal hemoglobinuria (PNH) (5.8 +/- 4.7 ng/ml, mean +/- S.D., n = 9) than in normal donors (2.0 +/- 0.8 ng/ml, mean +/- S.D., n = 15). The high level of soluble uPAR in PNH plasma competed with the membrane uPAR expressed by normal blood neutrophils for binding to urokinase-type plasminogen activator (uPA). We also found that uPA complexed with soluble uPAR was partly resistant to inactivation by plasminogen activator inhibitors in the plasma, although uPA was inactivated similarly by plasma containing high and low levels of uPAR. PNH-affected blood cells are deficient in urokinase-type PAR, a glycosyl-phosphatidylinositol (GPI)-anchored protein. The deficiency of uPAR on PNH-affected leukocytes and the increased soluble uPAR in the PNH plasma may synergistically contribute to the development of thrombosis in PNH by inhibiting the cell-associated fibrinolytic activity.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9114600     DOI: 10.1016/s0925-5710(96)00559-2

Source DB:  PubMed          Journal:  Int J Hematol        ISSN: 0925-5710            Impact factor:   2.490


  8 in total

Review 1.  Paroxysmal nocturnal hemoglobinuria: a complement-mediated hemolytic anemia.

Authors:  Amy E DeZern; Robert A Brodsky
Journal:  Hematol Oncol Clin North Am       Date:  2015-03-07       Impact factor: 3.722

2.  Upregulation of monocyte urokinase plasminogen activator receptor during human endotoxemia.

Authors:  P E Dekkers; T ten Hove; A A te Velde; S J van Deventer; T van Der Poll
Journal:  Infect Immun       Date:  2000-04       Impact factor: 3.441

3.  Diagnostic significance of measurement of the receptor for urokinase-type plasminogen activator on granulocytes and in plasma from patients with paroxysmal nocturnal hemoglobinuria.

Authors:  Weiqiang Gao; Zhaoyue Wang; Xia Bai; Yuyun Li; Changgeng Ruan
Journal:  Int J Hematol       Date:  2002-05       Impact factor: 2.490

4.  Loss of expression of neutrophil proteinase-3: a factor contributing to thrombotic risk in paroxysmal nocturnal hemoglobinuria.

Authors:  Anna M Jankowska; Hadrian Szpurka; Mark Calabro; Sanjay Mohan; Andrew E Schade; Michael Clemente; Roy L Silverstein; Jaroslaw P Maciejewski
Journal:  Haematologica       Date:  2011-05-05       Impact factor: 9.941

5.  Increased soluble urokinase plasminogen activator receptor (suPAR) is associated with thrombosis and inhibition of plasmin generation in paroxysmal nocturnal hemoglobinuria (PNH) patients.

Authors:  Elaine M Sloand; Loretta Pfannes; Phillip Scheinberg; Kenneth More; Colin O Wu; McDonald Horne; Neal S Young
Journal:  Exp Hematol       Date:  2008-10-26       Impact factor: 3.084

6.  Paroxysmal nocturnal hemoglobinuria: pathophysiology, natural history and treatment options in the era of biological agents.

Authors:  Antonio M Risitano; Bruno Rotoli
Journal:  Biologics       Date:  2008-06

Review 7.  The interaction between the complement system and hemostatic factors.

Authors:  Selin Oncul; Vahid Afshar-Kharghan
Journal:  Curr Opin Hematol       Date:  2020-09       Impact factor: 3.218

Review 8.  Laboratory studies for paroxysmal nocturnal hemoglobinuria, with emphasis on flow cytometry.

Authors:  Margarida Lima
Journal:  Pract Lab Med       Date:  2020-03-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.