Literature DB >> 9114396

Use of the Treponema pallidum-specific captia syphilis IgG assay in conjunction with the rapid plasma reagin to test for syphilis.

B S Reisner1, L M Mann, C A Tholcken, R T Waite, G L Woods.   

Abstract

The Captia Syphilis IgG enzyme immunoassay (EIA) was evaluated for use in conjunction with the rapid plasma reagin test (RPR) as a method to test for syphilis. A total of 1,288 serum specimens were tested by the routine laboratory protocol of the RPR followed by microhemagluttination assay for Treponema pallidum (MHA-TP) testing of RPR-reactive sera as well as the EIA-RPR protocol in which the automated EIA followed by a manual RPR test for EIA-positive specimens is used. When using the routine protocol, 131 specimens were initially reactive by the RPR, and 113 of these were reactive by MHA-TP. When using the EIA-RPR protocol, 170 specimens were initially positive by EIA, and of these, 112 were RPR reactive, indicating active disease. When compared to the routine protocol, the EIA-RPR protocol had sensitivity, specificity, and positive and negative predictive values of 96.5, 99.7, 97.3, and 99.7%, respectively. After resolution of discrepancies by additional testing, the adjusted sensitivity, specificity, and positive and negative predictive values were 100, 99.8, 98.3, and 100%, respectively. This evaluation demonstrates that when used in conjunction with the RPR, the Captia Syphilis EIA is a reliable method by which to test for syphilis.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9114396      PMCID: PMC232718          DOI: 10.1128/jcm.35.5.1141-1143.1997

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Enzyme immunoassay for anti-treponemal IgG: screening or confirmatory test?

Authors:  H Young; A Moyes; A McMillan; J Patterson
Journal:  J Clin Pathol       Date:  1992-01       Impact factor: 3.411

Review 2.  Syphilis.

Authors:  S A Larsen
Journal:  Clin Lab Med       Date:  1989-09       Impact factor: 1.935

3.  Comparison of CAPTIA syphilis G enzyme immunoassay with rapid plasma reagin test for detection of syphilis.

Authors:  R P Silletti
Journal:  J Clin Microbiol       Date:  1995-07       Impact factor: 5.948

4.  Evaluation of the Captia enzyme immunoassays for detection of immunoglobulins G and M to Treponema pallidum in syphilis.

Authors:  J C Lefevre; M A Bertrand; R Bauriaud
Journal:  J Clin Microbiol       Date:  1990-08       Impact factor: 5.948

5.  In vitro cultivation of Treponema pallidum: independent confirmation.

Authors:  S J Norris
Journal:  Infect Immun       Date:  1982-04       Impact factor: 3.441

Review 6.  Laboratory diagnosis and interpretation of tests for syphilis.

Authors:  S A Larsen; B M Steiner; A H Rudolph
Journal:  Clin Microbiol Rev       Date:  1995-01       Impact factor: 26.132

7.  Screening for treponemal infection by a new enzyme immunoassay.

Authors:  H Young; A Moyes; A McMillan; D H Robertson
Journal:  Genitourin Med       Date:  1989-04

8.  Evaluation of a Treponema pallidum enzyme immunoassay as a screening test for syphilis.

Authors:  N E Hooper; D C Malloy; S Passen
Journal:  Clin Diagn Lab Immunol       Date:  1994-07

9.  Cultivation of virulent Treponema pallidum in tissue culture.

Authors:  A H Fieldsteel; D L Cox; R A Moeckli
Journal:  Infect Immun       Date:  1981-05       Impact factor: 3.441

  9 in total
  9 in total

1.  Evaluation of an enzyme immunoassay technique for detection of antibodies against Treponema pallidum.

Authors:  Rita Castro; Emília S Prieto; Irene Santo; Jacinta Azevedo; Filomena da L Exposto
Journal:  J Clin Microbiol       Date:  2003-01       Impact factor: 5.948

2.  It is time to use treponema-specific antibody screening tests for diagnosis of syphilis.

Authors:  Michael J Loeffelholz; Matthew J Binnicker
Journal:  J Clin Microbiol       Date:  2011-11-16       Impact factor: 5.948

3.  Performance of CAPTIA SelectSyph-G enzyme-linked immunosorbent assay in syphilis testing of a high-risk population: analysis of discordant results.

Authors:  Vladana Woznicová; Zuzana Valisová
Journal:  J Clin Microbiol       Date:  2007-04-18       Impact factor: 5.948

4.  Clinical utility of a competitive ELISA to detect antibodies against Treponema pallidum.

Authors:  J Gutiérrez; M J Vergara; M J Soto; G Piédrola; M d Maroto
Journal:  J Clin Lab Anal       Date:  2000       Impact factor: 2.352

5.  Clinical comparison of the Treponema pallidum CAPTIA syphilis-G enzyme immunoassay with the fluorescent treponemal antibody absorption immunoglobulin G assay for syphilis testing.

Authors:  V W Halling; M F Jones; J E Bestrom; A D Wold; J E Rosenblatt; T F Smith; F R Cockerill
Journal:  J Clin Microbiol       Date:  1999-10       Impact factor: 5.948

6.  Evaluation of the LIAISON chemiluminescence immunoassay for diagnosis of syphilis.

Authors:  Carrie S Knight; Mary A Crum; Robert W Hardy
Journal:  Clin Vaccine Immunol       Date:  2007-04-25

7.  Comparative evaluation of 15 serological assays for the detection of syphilis infection.

Authors:  M J Cole; K R Perry; J V Parry
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2007-10       Impact factor: 3.267

8.  Comparative study of Treponemal and non-Treponemal test for screening of blood donated at a blood center.

Authors:  Narinder Kaur Naidu; Z S Bharucha; Vandana Sonawane; Imran Ahmed
Journal:  Asian J Transfus Sci       Date:  2012-01

9.  Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital.

Authors:  Aseem K Tiwari; Prashant K Pandey; Ravi C Dara; Ganesh S Rawat; Vimarsh Raina; Richa Bhargava
Journal:  Asian J Transfus Sci       Date:  2015 Jan-Jun
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.