Literature DB >> 9113574

Change in capsulorhexis size after implantation of three types of intraocular lenses.

M Gonvers1, M Sickenberg, G van Melle.   

Abstract

PURPOSE: To compare the change in size of continuous curvilinear capsulorhexis (CCC) used for implantation of three types of intraocular lenses (IOLs) and to determine the role of postoperative inflammation, initial CCC dimension, haptic design, and optic material.
SETTING: Hôpital Ophtalmique Universitaire Jules Gonin, Lausanne, Switzerland.
METHOD: Twenty-nine three-piece, silicone/poly(methyl methacrylate) (PMMA) IOLs (lovision 127), 26 one-piece PMMA IOLs (Pharmacia 812A), and 27 plate-haptic silicone IOLs (Staar AA4203) were implanted in the capsular bag after phacoemulsification. Photographs of the CCCs taken 1 day and 6 months after surgery were scanned and digitized on a computer. Using different software, the surface of the CCC was measured and the 6 month change evaluated. Flare, measured the day before surgery and postoperatively at days 1, 7, 30, and 180, was integrated to obtain a global estimate of inflammation during the 180 day follow-up.
RESULTS: The CCCs used with three-piece, silicone/PMMA IOLs showed little changes in surface, with a mean enlargement of +0.57 mm2 +/- 1.15 (SD) (+3.5%). The CCCs used with the one-piece PMMA IOLs had a slight tendency to constrict, with a mean surface decrease of -0.59 +/- 2.16 mm2 (-4.3%). The CCCs used with plate-haptic silicone IOLs showed a marked and statistically significant constriction, with a mean decrease of -2.55 +/- 3.51 mm2 (-14.4%). The change in CCC size was not associated with the integrated flare, and no correlation was found between the initial CCC size and the magnitude of change. There was no statistically significant difference in CCC change between the PMMA optic IOL (Pharmacia) and silicone optic IOL (lovision and Staar) groups. The CCC in the plate-haptic IOL (Staar) group showed a significant (P < .0002) constriction when compared with that in the loop-haptic IOL (Pharmacia and lovision) group.
CONCLUSION: The IOLs' haptic design seemed to play a major role in the evolution of the CCC. The CCC constriction seen with the Staar IOLs was related to their plate haptics.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9113574     DOI: 10.1016/s0886-3350(97)80346-x

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Circular YAG laser anterior capsulotomy for anterior capsule contraction syndrome.

Authors:  Mohamed Nagy Elmohamady; Ashraf Elhabbak; Elham Abdelazim Gad
Journal:  Int Ophthalmol       Date:  2019-03-11       Impact factor: 2.031

2.  Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.

Authors:  D J Apple
Journal:  Trans Am Ophthalmol Soc       Date:  2000

3.  Effect of haptic material and number of intraocular lens on anterior capsule contraction after cataract surgery.

Authors:  Sun Young Kim; Ji Wook Yang; Young Chun Lee; Su-Young Kim
Journal:  Korean J Ophthalmol       Date:  2013-01-15

4.  Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

Authors:  Xuhua Tan; Haotian Lin; Zhuoling Lin; Jingjing Chen; Xiangchen Tang; Lixia Luo; Weirong Chen; Yizhi Liu
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889

5.  Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design.

Authors:  Soonwon Yang; Sung A Lim; Kyung-Sun Na; Choun-Ki Joo
Journal:  Korean J Ophthalmol       Date:  2017-02-02

Review 6.  Biomaterial Influence on Intraocular Lens Performance: An Overview.

Authors:  Cari Pérez-Vives
Journal:  J Ophthalmol       Date:  2018-03-15       Impact factor: 1.909

7.  Impact of anterior capsular polishing on capsule opacification rate in eyes undergoing femtosecond laser-assisted cataract surgery.

Authors:  Gitansha S Sachdev; B Soundarya; Shreyas Ramamurthy; Charanya Lakshmi; Ramamurthy Dandapani
Journal:  Indian J Ophthalmol       Date:  2020-05       Impact factor: 1.848

8.  Four-flanged prolene fixation for a toric trifocal intraocular lens of the double C-Loop design in an eye with severe capsular phimosis.

Authors:  Abdulhameed Hashim Mahmood; Mohammed Khalid Aljodaie; Anoud Faisal Alsaati
Journal:  Am J Ophthalmol Case Rep       Date:  2021-01-08

9.  Rapid Capsular Contraction with Secondary Intraocular Lens Dislocation Associated with Unspecified Rod-Cone Dystrophy: A Case Report.

Authors:  Jocelyn Lam; Bradley Sifrig; Hoon Jung
Journal:  Case Rep Ophthalmol       Date:  2018-02-14
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.