Literature DB >> 9109560

Fabric and elastic principal directions of cancellous bone are closely related.

A Odgaard1, J Kabel, B van Rietbergen, M Dalstra, R Huiskes.   

Abstract

Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much effort has been spent in expressing these relations, but the techniques and variables necessary for this have not been fully identified. It is obvious, however, that some measure of architectural anisotropy (fabric) is needed. Within the last few years, volume-based measures of fabric have been introduced as alternatives to the mean intercept length method, which has some theoretical problems. This paper seeks to answer which of four different fabric measures best predicts finite element calculated mechanical anisotropy directions. Twenty-nine cancellous bone specimens were three-dimensionally reconstructed using the automated serial sectioning technique. A series of large-scale finite-element analyses were performed on each of the three-dimensional reconstructions to calculate the compliance matrix for each specimen, from which the mechanical principal directions were derived. The architectural anisotropy was determined in three-dimensional space for each specimen using mean intercept length (MIL), volume orientation (VO), star volume distribution (SVD) and star length distribution (SLD). Each of the architectural anisotropy results were expressed by a fabric tensor. Architectural main directions were determined from the fabric tensors and compared with the FE-calculated mechanical anisotropy directions. All architectural measures predicted the mechanical main directions rather well, which supports the assumption that mechanical anisotropy directions are aligned with fabric directions. MIL showed a significant, though very small (1.4 degrees), deviation from the primary mechanical direction. VO had difficulty in determining secondary and tertiary mechanical directions; its mean deviation was 8.9 degrees. SVD and SLD provided marginally better predictors of mechanical anisotropy directions than MIL and VO.

Entities:  

Mesh:

Year:  1997        PMID: 9109560     DOI: 10.1016/s0021-9290(96)00177-7

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  42 in total

1.  Oreopithecus was a bipedal ape after all: evidence from the iliac cancellous architecture.

Authors:  L Rook; L Bondioli; M Köhler; S Moyà-Solà; R Macchiarelli
Journal:  Proc Natl Acad Sci U S A       Date:  1999-07-20       Impact factor: 11.205

2.  Role of structural anisotropy of biological tissues in poroelastic wave propagation.

Authors:  Luis Cardoso; Stephen C Cowin
Journal:  Mech Mater       Date:  2012-01       Impact factor: 3.266

3.  Do regional modifications in tissue mineral content and microscopic mineralization heterogeneity adapt trabecular bone tracts for habitual bending? Analysis in the context of trabecular architecture of deer calcanei.

Authors:  John G Skedros; Alex N Knight; Ryan W Farnsworth; Roy D Bloebaum
Journal:  J Anat       Date:  2012-01-06       Impact factor: 2.610

4.  Micro-CT-based screening of biomechanical and structural properties of bone tissue engineering scaffolds.

Authors:  Tim Van Cleynenbreugel; Jan Schrooten; Hans Van Oosterwyck; Jos Vander Sloten
Journal:  Med Biol Eng Comput       Date:  2006-06-27       Impact factor: 2.602

5.  Mechanical loading causes detectable changes in morphometric measures of trabecular structure in human cancellous bone.

Authors:  Yener N Yeni; Brenda Wu; Lily Huang; Daniel Oravec
Journal:  J Biomech Eng       Date:  2013-05       Impact factor: 2.097

6.  Cancellous bone and theropod dinosaur locomotion. Part I-an examination of cancellous bone architecture in the hindlimb bones of theropods.

Authors:  Peter J Bishop; Scott A Hocknull; Christofer J Clemente; John R Hutchinson; Andrew A Farke; Belinda R Beck; Rod S Barrett; David G Lloyd
Journal:  PeerJ       Date:  2018-10-31       Impact factor: 2.984

7.  Classification of trabeculae into three-dimensional rodlike and platelike structures via local inertial anisotropy.

Authors:  Branimir Vasilić; Chamith S Rajapakse; Felix W Wehrli
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

8.  Remodeling of the connective tissue microarchitecture of the lamina cribrosa in early experimental glaucoma.

Authors:  Michael D Roberts; Vicente Grau; Jonathan Grimm; Juan Reynaud; Anthony J Bellezza; Claude F Burgoyne; J Crawford Downs
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-09-20       Impact factor: 4.799

9.  Fabric dependence of quasi-waves in anisotropic porous media.

Authors:  Luis Cardoso; Stephen C Cowin
Journal:  J Acoust Soc Am       Date:  2011-05       Impact factor: 1.840

10.  Structural parameters of normal and osteoporotic human trabecular bone are affected differently by microCT image resolution.

Authors:  H Isaksson; J Töyräs; M Hakulinen; A S Aula; I Tamminen; P Julkunen; H Kröger; J S Jurvelin
Journal:  Osteoporos Int       Date:  2010-03-27       Impact factor: 4.507

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.