Literature DB >> 9106146

An oblique cylinder contrast-adjusted (OCCA) phantom to measure the accuracy of MRI brain lesion volume estimation schemes in multiple sclerosis.

P S Tofts1, G J Barker, M Filippi, M Gawne-Cain, M Lai.   

Abstract

A new OCCA phantom using Oblique Cylinders and Contrast Adjustment for measuring the accuracy of brain lesion volume estimation schemes is described. It uses obliquely oriented cylinders made from acrylic rod, mounted in a water bath, to give realistic partial volume errors. Image intensities are inverted, scaled, and shifted, and noise is added, to form images that have realistic values of lesion-white matter contrast (5-30%) and contrast-to-noise ratio (3-20%). Artificial gray matter, CSF (cerebrospinal fluid), and scalp lipid are added because these bright areas may determine how the gray level display window is set. The performance of manual and contouring methods for estimating lesion volume was measured for three observers and nine lesions with individual volumes from 0.3 to 6.2 ml. There was a large variation, depending on the choice of method, the observer, and the lesion contrast. Volumes were usually overestimated, with the error increasing at high contrasts. The average error in estimating total lesion volume was 17% (range -16% to +30%). The OCCA phantom may have a role in training observers to improve their accuracy (and hence inter- and intraobserver reproducibility).

Entities:  

Mesh:

Year:  1997        PMID: 9106146     DOI: 10.1016/s0730-725x(96)00339-6

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

Review 1.  Multicentre imaging measurements for oncology and in the brain.

Authors:  P S Tofts; D J Collins
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

Review 2.  Update on brain tumor imaging: from anatomy to physiology.

Authors:  S Cha
Journal:  AJNR Am J Neuroradiol       Date:  2006-03       Impact factor: 3.825

3.  Comparison of microvascular permeability measurements, K(trans), determined with conventional steady-state T1-weighted and first-pass T2*-weighted MR imaging methods in gliomas and meningiomas.

Authors:  S Cha; L Yang; G Johnson; A Lai; M-H Chen; T Tihan; M Wendland; W P Dillon
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

4.  FLAIR histogram segmentation for measurement of leukoaraiosis volume.

Authors:  C R Jack; P C O'Brien; D W Rettman; M M Shiung; Y Xu; R Muthupillai; A Manduca; R Avula; B J Erickson
Journal:  J Magn Reson Imaging       Date:  2001-12       Impact factor: 4.813

Review 5.  Nuclear magnetic resonance monitoring of treatment and prediction of outcome in multiple sclerosis.

Authors:  D H Miller; A J Thompson
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-10-29       Impact factor: 6.237

6.  Object strength--an accurate measure for small objects that is insensitive to partial volume effects.

Authors:  P S Tofts; N C Silver; G J Barker; A Gass
Journal:  MAGMA       Date:  2005-07-18       Impact factor: 2.310

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.