Long-term vascular access for hemodialysis using silicon dual-lumen catheters with guidewire replacement of catheters for technique salvage.

K McLaughlin1, B Jones, R Mactier, C Porteus.   

Abstract

Difficulties in creating vascular access in patients on hemodialysis are encountered in most dialysis centers. This is usually due to a lack of suitable peripheral vessels due to previous access surgery in patients on long-term hemodialysis, but also may be seen in some patients de novo, particularly diabetics and patients with peripheral vascular disease. Surgical techniques used to overcome this problem vary depending on patient characteristics and, to a certain extent, on local expertise/preference. We report our experience of using silicon dual-lumen hemodialysis catheters over a 3-year period; during this time, 54 catheters were inserted into 32 hemodialysis patients. The indication for this procedure in 52 catheters (31 patients) was either exhausted vascular access or obvious difficulty identifying a suitable peripheral blood vessel. Of the catheters inserted, 20 were placed into subclavian veins by primary insertion (ie, patients did not have existing subclavian catheter); 34 were replaced over a guidewire (a procedure used to allow technique salvage). The catheter survival rate was 72.7% at 90 days and 48.7% at 1 year. Corresponding rates at 90 days and 1 year for technique survival were 93.3% and 81.8%, respectively. The mean catheter and technique survival was 387 (95% confidence intervals [CIs], 273, 502) and 844 (95% CIs, 684, 1,005) days, respectively. Poor flow accounted for 70.4% of catheter failures and, despite 18 episodes of catheter-related sepsis, no catheters were lost due to infection. Factors identified as leading to reduced catheter survival were left-sided placement and catheter tip placement in the superior vena cava (as opposed to right atrial placement). We did not observe poorer survival or increased sepsis in catheters replaced over a guidewire, and would advocate this technique as a means of salvage in this group of patients.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9100044     DOI: 10.1016/s0272-6386(97)90337-1

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  2 in total

Review 1.  Is regenerative medicine a new hope for kidney replacement?

Authors:  Maciej Nowacki; Tomasz Kloskowski; Marta Pokrywczyńska; Łukasz Nazarewski; Arkadiusz Jundziłł; Katarzyna Pietkun; Dominik Tyloch; Marta Rasmus; Karolina Warda; Samy L Habib; Tomasz Drewa
Journal:  J Artif Organs       Date:  2014-04-19       Impact factor: 1.731

2.  The surface topography of silicone breast implants mediates the foreign body response in mice, rabbits and humans.

Authors:  Joshua C Doloff; Omid Veiseh; Roberto de Mezerville; Marcos Sforza; Tracy Ann Perry; Jennifer Haupt; Morgan Jamiel; Courtney Chambers; Amanda Nash; Samira Aghlara-Fotovat; Jessica L Stelzel; Stuart J Bauer; Sarah Y Neshat; John Hancock; Natalia Araujo Romero; Yessica Elizondo Hidalgo; Isaac Mora Leiva; Alexandre Mendonça Munhoz; Ardeshir Bayat; Brian M Kinney; H Courtney Hodges; Roberto N Miranda; Mark W Clemens; Robert Langer
Journal:  Nat Biomed Eng       Date:  2021-06-21       Impact factor: 25.671

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.