Literature DB >> 9094075

Coronary flow and coronary flow reserve measurements in humans with breath-held magnetic resonance phase contrast velocity mapping.

C P Davis1, P F Liu, M Hauser, S C Göhde, G K von Schulthess, J F Debatin.   

Abstract

Objective evidence for coronary lesion significance can be obtained with ischemic stress testing. Since flow-limiting stenoses have already undergone compensatory vasodilatation to maintain flow, the response to vasoactive stimulation is dampened. The degree of response limitation is reflected by the coronary flow reserve (CFR). Absolute volume flow rates can be accurately and noninvasively measured with MRI techniques. The purpose was to assess the ability to measure coronary volume flow rate noninvasively, and characterize the effect of pharmacologic stress on coronary flow quantitatively by using ultrafast, breath-held segmented k-space phase-contrast-MR imaging (PC-MRI). Ten healthy volunteers were examined by using ultrafast breath-held PC-MRI. Coronary volume flow rates were measured in the anterior descending coronary artery (LAD) at rest and following intravenous administration of dipyridamole. CFR was determined based on these data. Mean LAD volume flow rates increased from 38 +/- 11 ml/min before application of dipyridamole to 169 +/- 42 ml/min. The mean CFR amounted to 5.0 +/- 2.6 (median = 4.15). This study demonstrates the feasibility of breath-held PC-MRI to noninvasively quantify coronary volume flow rates over the cardiac cycle. Pharmacologically induced changes in volume flow rate and thus CFR can be quantitated.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9094075     DOI: 10.1002/mrm.1910370410

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  MR-based coronary artery blood velocity measurements in patients without coronary artery disease.

Authors:  M Schiemann; F Bakhtiary; V Hietschold; A Koch; A Esmaeili; H Ackermann; A Moritz; T J Vogl; N D Abolmaali
Journal:  Eur Radiol       Date:  2006-01-13       Impact factor: 5.315

2.  Intravascular ultrasound catheter to enhance microbubble-based drug delivery via acoustic radiation force.

Authors:  Joseph P Kilroy; Alexander L Klibanov; Brian R Wamhoff; John A Hossack
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-10       Impact factor: 2.725

3.  Shared velocity encoding: a method to improve the temporal resolution of phase-contrast velocity measurements.

Authors:  Hung-Yu Lin; Jacob A Bender; Yu Ding; Yiu-Cho Chung; Alice M Hinton; Michael L Pennell; Kevin K Whitehead; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

4.  Noninterleaved velocity encodings for improved temporal and spatial resolution in phase-contrast magnetic resonance imaging.

Authors:  Craig A Hamilton; Jennifer H Jordan; Robert A Kraft; W Gregory Hundley
Journal:  J Comput Assist Tomogr       Date:  2010-07       Impact factor: 1.826

5.  Coronary Endothelial Dysfunction in Women With Type 2 Diabetes Measured by Coronary Phase Contrast Flow Velocity Magnetic Resonance Imaging.

Authors:  Christopher D Maroules; Alice Y Chang; Melanie S Kotys-Traughber; Ronald M Peshock
Journal:  J Investig Med       Date:  2015-10       Impact factor: 2.895

6.  Assessment of coronary blood flow in humans using phase difference MR imaging. Comparison with intracoronary Doppler flow measurement.

Authors:  W Kessler; W Moshage; A Galland; D Zink; S Achenbach; W Nitz; G Laub; K Bachmann
Journal:  Int J Card Imaging       Date:  1998-06

7.  Coronary Flow Assessment Using Accelerated 4D Flow MRI With Respiratory Motion Correction.

Authors:  Carmen P S Blanken; Eric M Schrauben; Eva S Peper; Lukas M Gottwald; Bram F Coolen; Diederik F van Wijk; Jan J Piek; Gustav J Strijkers; R Nils Planken; Pim van Ooij; Aart J Nederveen
Journal:  Front Bioeng Biotechnol       Date:  2021-08-17

8.  Quantifying coronary sinus flow and global LV perfusion at 3T.

Authors:  Karin Markenroth Bloch; Marcus Carlsson; Håkan Arheden; Freddy Ståhlberg
Journal:  BMC Med Imaging       Date:  2009-06-11       Impact factor: 1.930

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.