Literature DB >> 9091528

Sustained local delivery of dexamethasone by a novel intravascular eluting stent to prevent restenosis in the porcine coronary injury model.

A M Lincoff1, J G Furst, S G Ellis, R J Tuch, E J Topol.   

Abstract

OBJECTIVES: This study sought to assess the feasibility, safety and efficacy of sustained intracoronary delivery of dexamethasone by a novel polymer-coated eluting stent.
BACKGROUND: Development of techniques to provide sustained local drug delivery has focused on polymers as matrices for drug incorporation and elution.
METHODS: A tantalum wire stent was coated with dexamethasone (0.8 mg) suspended in a matrix of either low (approximately 80 kD) or high (approximately 321 kD) molecular weight poly-L-lactic acid (PLLA [0.4 mg]). Uncoated stents, stents coated with PLLA or stents coated with dexamethasone in PLLA were overexpanded by 30% to the normal vessel diameter in the coronary arteries of juvenile farm pigs. Animals were euthanized 28 days later, and neointimal thicknesses were measured. Additional pigs underwent placement of stents coated with high molecular weight PLLA-dexamethasone for assessment of arterial tissue and serum concentrations of dexamethasone at 1 h and 1, 2, 10 and 28 days after stent implantation.
RESULTS: In vitro dexamethasone release occurred over the first 6 days. Stents coated with low molecular weight PLLA produced an intense inflammatory neointimal response. Stents utilizing the high molecular weight PLLA were well tolerated within the coronary vessel during the 28-day experiment. However, dexamethasone did not decrease neointimal hyperplasia. Dexamethasone concentrations in the arterial tissue were approximately 300,000-fold higher than those in the serum 24 h after stent implantation, remaining approximately 3,000-fold higher at 28 days.
CONCLUSIONS: The eluting stent utilizing high molecular weight PLLA appeared to be a well tolerated and effective means of providing sustained, site-specific drug delivery to the porcine coronary artery wall for at least 28 days.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9091528     DOI: 10.1016/s0735-1097(96)00584-0

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  32 in total

1.  Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries.

Authors:  D M Whelan; W J van der Giessen; S C Krabbendam; E A van Vliet; P D Verdouw; P W Serruys; H M van Beusekom
Journal:  Heart       Date:  2000-03       Impact factor: 5.994

2.  A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits.

Authors:  M Peuster; P Wohlsein; M Brügmann; M Ehlerding; K Seidler; C Fink; H Brauer; A Fischer; G Hausdorf
Journal:  Heart       Date:  2001-11       Impact factor: 5.994

3.  Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?

Authors:  B Heublein; R Rohde; V Kaese; M Niemeyer; W Hartung; A Haverich
Journal:  Heart       Date:  2003-06       Impact factor: 5.994

4.  Tissue biocompatibility of new biodegradable drug-eluting stent materials.

Authors:  Ilkka Uurto; Andres Kotsar; Taina Isotalo; Joonas Mikkonen; Paula M Martikainen; Minna Kellomäki; Pertti Törmälä; Teuvo L J Tammela; Martti Talja; Juha-Pekka Salenius
Journal:  J Mater Sci Mater Med       Date:  2007-04-17       Impact factor: 3.896

5.  In vitro study of drug-eluting stent coatings based on poly(L-lactide) incorporating cyclosporine A - drug release, polymer degradation and mechanical integrity.

Authors:  Katrin Sternberg; Sven Kramer; Claudia Nischan; Niels Grabow; Thomas Langer; Gerhard Hennighausen; Klaus-Peter Schmitz
Journal:  J Mater Sci Mater Med       Date:  2007-03-27       Impact factor: 3.896

6.  Unconstrained recovery characterization of shape-memory polymer networks for cardiovascular applications.

Authors:  Christopher Michael Yakacki; Robin Shandas; Craig Lanning; Bryan Rech; Alex Eckstein; Ken Gall
Journal:  Biomaterials       Date:  2007-02-02       Impact factor: 12.479

Review 7.  Therapeutic manipulation of glucocorticoid metabolism in cardiovascular disease.

Authors:  Patrick W F Hadoke; Javaid Iqbal; Brian R Walker
Journal:  Br J Pharmacol       Date:  2009-02-23       Impact factor: 8.739

Review 8.  Pathology of atherosclerosis and stenting.

Authors:  Frank D Kolodgie; Gaku Nakazawa; Giuseppe Sangiorgi; Elena Ladich; Allen P Burke; Renu Virmani
Journal:  Neuroimaging Clin N Am       Date:  2007-08       Impact factor: 2.264

Review 9.  Biomimetic strategies based on viruses and bacteria for the development of immune evasive biomaterials.

Authors:  Matthew T Novak; James D Bryers; William M Reichert
Journal:  Biomaterials       Date:  2009-01-29       Impact factor: 12.479

10.  A review of the development of a vehicle for localized and controlled drug delivery for implantable biosensors.

Authors:  Upkar Bhardwaj; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2008-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.