Literature DB >> 9086397

The effects of micromachined surfaces on formation of bonelike tissue on subcutaneous implants as assessed by radiography and computer image processing.

B Chehroudi1, D McDonnell, D M Brunette.   

Abstract

Surface topography varies widely among commercially available orthopedic and dental implants. While it is generally accepted that the surface topography of an implant influences the formation of bone and affects its performance, few systematic studies have dealt with this important feature. Quantification of the mineralized tissue at the implant interface has typically been attempted using histologic methods or conventional radiographic procedures. However, histologic methods are often technically demanding and time consuming, whereas conventional radiographic procedures lack resolution and sensitivity to identify small areas of mineralization. The objective of this study was to study systematically the effects of micromachined surfaces on bone formation by applying digital radiographic techniques to identify and quantify mineralized tissue. Titanium-coated epoxy replicas of 19 different micromachined grooved or pitted surfaces that ranged between 30 and 120 microns deep, as well as smooth control surfaces, were implanted percutaneously and fixed to the parietal bone of rats. After 8 weeks the implants and attached tissue were removed and processed for light and electron microscopy. A total of 316 implant surfaces were processed, radiographed using conventional and digital techniques, and sectioned for histologic observations. The area of the bonelike tissue and its density were calculated using National Institutes of Health Image software. Mineralization was frequently noted at the interface of some types of micromachined surface but rarely on smooth surfaces. The presence of bone in histologic sections and areas identified as bone through digital radiography and image processing correlated strongly. The frequency of bonelike foci formation decreased as the depth of the grooves increased. In contrast, mineralization occurred more frequently as the depth of the pit increased. In addition, bonelike foci were oriented along the long axis of the grooves. It is thus feasible that the bonelike tissue is shaped, directed, or engineered to a predetermined configuration which is dictated by the surface topography. This study indicated that surface topography influences the frequency as well as the amount of bone deposited adjacent to implants, and mineralized product can be guided by the surface topography. Moreover, digital radiography and image processing can be used reliably to identify and quantify mineralized tissue at the implant interface.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9086397     DOI: 10.1002/(sici)1097-4636(19970305)34:3<279::aid-jbm2>3.0.co;2-h

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  9 in total

Review 1.  Biology on a chip: microfabrication for studying the behavior of cultured cells.

Authors:  Nianzhen Li; Anna Tourovskaia; Albert Folch
Journal:  Crit Rev Biomed Eng       Date:  2003

2.  Load bearing capacity of bone anchored fiber-reinforced composite device.

Authors:  Ahmed Mansour Ballo; Lippo V Lassila; Pekka K Vallittu; Timo O Närhi
Journal:  J Mater Sci Mater Med       Date:  2007-06-09       Impact factor: 3.896

Review 3.  Enhancing Stent Effectiveness with Nanofeatures.

Authors:  Nicole Bassous; John P Cooke; Thomas J Webster
Journal:  Methodist Debakey Cardiovasc J       Date:  2016-09

4.  Evaluation of Biocompatibility of Different Membrane Surfaces Using Unrestricted Somatic Stem Cells.

Authors:  Lara Schorn; Jörg Handschel; Julian Lommen; Felix Paulssen VON Beck; Rita Depprich; Norbert Kübler; Henrik Holtmann
Journal:  In Vivo       Date:  2019 Sep-Oct       Impact factor: 2.155

5.  The influence of bone formation on anchoring percutaneous devices with titanium fibre mesh flanges.

Authors:  M M Shalabi; X F Walboomers; J A Jansen
Journal:  J Mater Sci Mater Med       Date:  2004-07       Impact factor: 3.896

6.  Migration of periodontal ligament fibroblasts on nanometric topographical patterns: influence of filopodia and focal adhesions on contact guidance.

Authors:  Douglas W Hamilton; Christine J Oates; Abdollah Hasanzadeh; Silvia Mittler
Journal:  PLoS One       Date:  2010-12-01       Impact factor: 3.240

Review 7.  Nanomaterials and synergistic low-intensity direct current (LIDC) stimulation technology for orthopedic implantable medical devices.

Authors:  Rohan A Shirwaiker; Meghan E Samberg; Paul H Cohen; Richard A Wysk; Nancy A Monteiro-Riviere
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2013-01-17

8.  Accentuated osseointegration in osteogenic nanofibrous coated titanium implants.

Authors:  Siddhartha Das; Kanchan Dholam; Sandeep Gurav; Kiran Bendale; Arvind Ingle; Bhabani Mohanty; Pradip Chaudhari; Jayesh R Bellare
Journal:  Sci Rep       Date:  2019-12-09       Impact factor: 4.379

9.  Effect of cyclic precalcification of nanotubular TiO2 layer on the bioactivity of titanium implant.

Authors:  Il Song Park; Eun Jin Yang; Tae Sung Bae
Journal:  Biomed Res Int       Date:  2013-08-29       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.