Literature DB >> 9085754

Practical coronary physiology. Clinical application of the Doppler flow velocity guide wire.

R G Bach1, M J Kern.   

Abstract

Coronary angiography incompletely delineates the physiologic consequences of many epicardial stenoses. Intracoronary translesional flow velocity measurements using the Doppler flow wire during cardiac catheterization provide immediate data discriminating the physiologic significance of coronary stenoses. The validity and accuracy of the flow wire for analyzing lesion hemodynamic significance have been confirmed in multiple studies. Flow velocity analysis provides objective criteria for refining the selection of cases for revascularization, and prospective clinical data have confirmed the safety of deferring intervention on lesions with normal physiologic assessment. Translesional and distal coronary flow velocity dynamics during procedures also provide immediate data assessing the physiologic adequacy of intervention. Impaired postintervention distal coronary flow velocity and vasodilator reserve can predict subsequent clinical events, and comparisons of flow velocity indices prestenting and poststenting suggest that physiologically inadequate results of angioplasty may be improved by additional intervention. Flow velocity assessment may also have utility in profiling the adequacy of infarct artery reperfusion following acute myocardial infarction. Evidence has been accumulated to support use of Doppler flow velocity analysis as a clinically relevant technique for improving both diagnostic and therapeutic aspects of cardiovascular medicine.

Entities:  

Mesh:

Year:  1997        PMID: 9085754     DOI: 10.1016/s0733-8651(05)70320-9

Source DB:  PubMed          Journal:  Cardiol Clin        ISSN: 0733-8651            Impact factor:   2.213


  4 in total

1.  Safety of coronary reactivity testing in women with no obstructive coronary artery disease: results from the NHLBI-sponsored WISE (Women's Ischemia Syndrome Evaluation) study.

Authors:  Janet Wei; Puja K Mehta; B Delia Johnson; Bruce Samuels; Saibal Kar; R David Anderson; Babak Azarbal; John Petersen; Barry Sharaf; Eileen Handberg; Chrisandra Shufelt; Kamlesh Kothawade; George Sopko; Amir Lerman; Leslee Shaw; Sheryl F Kelsey; Carl J Pepine; C Noel Bairey Merz
Journal:  JACC Cardiovasc Interv       Date:  2012-06       Impact factor: 11.195

2.  Characteristics of the flow velocity-pressure gradient relation in the assessment of stenoses: an in vitro study.

Authors:  K M J Marques; N Westerhof
Journal:  Neth Heart J       Date:  2008-05       Impact factor: 2.380

3.  Z2D3 imaging: fringe or frontier?

Authors:  H W Strauss
Journal:  J Nucl Cardiol       Date:  1998 Nov-Dec       Impact factor: 5.952

4.  Cerebral aneurysms treated with flow-diverting stents: computational models with intravascular blood flow measurements.

Authors:  M R Levitt; P M McGah; A Aliseda; P D Mourad; J D Nerva; S S Vaidya; R P Morton; B V Ghodke; L J Kim
Journal:  AJNR Am J Neuroradiol       Date:  2013-07-18       Impact factor: 3.825

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.