Literature DB >> 9084345

Assessment of isokinetic and hand-held dynamometer measures of shoulder rotator strength among individuals with spinal cord injury.

L A May1, R S Burnham, R D Steadward.   

Abstract

OBJECTIVE: To determine the intrarater reliability of the hand-held dynamometer (HHD) for the measurement of shoulder rotation and to examine the relationship between the peak force values of the HHD and the isokinetic dynamometer. PARTICIPANTS: Twenty-five spinal cord injured individuals, 12 persons with paraplegia and 13 persons with tetraplegia between the ages of 18 and 42 years, were recruited from the community.
SETTING: Private practice clinic. PROCEDURES: All participants were tested with the HHD by one examiner to determine reliability. On the same day, these participants underwent isokinetic testing to determine the relationship of the HHD and Cybex dynamometer measurements.
RESULTS: The intraclass correlation coefficients for the intrarater reliability ranged from .89 to .96. The Pearson product moment correlation was used to analyze the relationship between the two devices. All coefficients (.52 to .88) were statistically significant (p < .01); however, separate analyses for the persons with paraplegia and tetraplegia differed considerably. There was substantial variability of the isokinetic strength values at the lower levels of isometric strength.
CONCLUSIONS: The HHD can be used reliably to measure shoulder rotation in paraplegic and tetraplegic spinal cord injured individuals. Although it appears that the relationship between HHD and isokinetic measurement is poor for the participants with tetraplegia, the variability of the isokinetic scores indicates that this observation may be a function of the method of isokinetic measurements. Further study with a modified isokinetic testing protocol is needed to clarify the results of the participants with tetraplegia.

Entities:  

Mesh:

Year:  1997        PMID: 9084345     DOI: 10.1016/s0003-9993(97)90029-0

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  7 in total

1.  Handgrip Strength Cutoff Points for Functional Independence and Wheelchair Ability in Men With Spinal Cord Injury.

Authors:  Frederico Ribeiro Neto; Rodrigo R Gomes Costa; Jefferson R Dorneles; Carlos W Gonçalves; João H C L Veloso; Rodrigo L Carregaro
Journal:  Top Spinal Cord Inj Rehabil       Date:  2021-08-13

2.  Peak Torque Prediction Using Handgrip and Strength Predictors in Men and Women With Motor Complete Spinal Cord Injury.

Authors:  Frederico Ribeiro Neto; Jefferson Rodrigues Dorneles; João Henrique Carneiro Leão Veloso; Carlos Wellington Gonçalves; Rodrigo Rodrigues Gomes Costa
Journal:  Top Spinal Cord Inj Rehabil       Date:  2021-08-13

3.  Validity of the Handheld Dynamometer Compared with an Isokinetic Dynamometer in Measuring Peak Hip Extension Strength.

Authors:  Heather Keep; Levana Luu; Ayli Berson; S Jayne Garland
Journal:  Physiother Can       Date:  2016       Impact factor: 1.037

4.  Practice day may be unnecessary prior to testing knee extensor strength in young healthy adults.

Authors:  Jamie E Hibbert; Anthony S Kulas; Patrick M Rider; Zachary J Domire
Journal:  Int Biomech       Date:  2020-12

5.  Efficacy of pre-exercise low-level laser therapy on isokinetic muscle performance in individuals with type 2 diabetes mellitus: study protocol for a randomized controlled trial.

Authors:  Cid André Fidelis de Paula Gomes; Ernesto Cesar Pinto Leal-Junior; Daniela Aparecida Biasotto-Gonzalez; Yasmin El-Hage; Fabiano Politti; Tabajara de Oliveira Gonzalez; Almir Vieira Dibai-Filho; Adriano Rodrigues de Oliveira; Marcelo Frigero; Fernanda Colella Antonialli; Adriane Aver Vanin; Paulo de Tarso Camillo de Carvalho
Journal:  Trials       Date:  2014-04-09       Impact factor: 2.279

6.  Inter- and intrarater reliability of goniometry and hand held dynamometry for patients with subacromial impingement syndrome.

Authors:  Georg Fieseler; Kevin G Laudner; Lars Irlenbusch; Henrike Meyer; Stephan Schulze; Karl-Stefan Delank; Souhail Hermassi; Thomas Bartels; René Schwesig
Journal:  J Exerc Rehabil       Date:  2017-12-27

7.  RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION.

Authors:  Rodrigo Antunes de Vasconcelos; Débora Bevilaqua-Grossi; Antonio Carlos Shimano; Cleber Jansen Paccola; Tânia Fátima Salvini; Christiane Lanatovits Prado; Wilson A Mello Junior
Journal:  Rev Bras Ortop       Date:  2015-11-16
  7 in total