Literature DB >> 9068133

Endoluminal exclusion of an iliac artery aneurysm by Wallstent endoprosthesis and PTFE vascular graft.

Z Krajcer1, R Khoshnevis, D R Leachman, H Herman.   

Abstract

Aneurysms isolated in the iliac artery and measuring more than 3 cm in diameter are associated with an increased rate of rupture and a high mortality rate. The current therapy recommended for such aneurysms is surgical exclusion. Percutaneous exclusion of isolated iliac aneurysms with covered or uncovered stents, however, reduces the morbidity and mortality rates associated with surgery by obviating the need for general anesthesia, avoiding significant blood loss, and reducing in-hospital recuperation time. We report the case of a patient who had an isolated atherosclerotic iliac artery aneurysm that was successfully excluded percutaneously by use of an endovascular prosthesis (WALLSTENT Endoprosthesis) made by Schneider (USA), Inc; Minneapolis, Minn, in conjunction with the Thin-Walled GORE-TEX (polytetrafluoroethylene) Vascular Graft (W.L. Gore & Associates, Inc.; Flagstaff, Ariz). Although various stent devices have been used recently in conjunction with a polytetrafluoroethylene graft to exclude peripheral arterial aneurysms, the self-expandable WALLSTENT has not been used with polytetrafluoroethylene in this fashion and for this purpose until recently. We present herein the technical aspects of endoluminal exclusion of the isolated iliac artery aneurysm with this composite stent-graft.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9068133      PMCID: PMC325391     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  13 in total

1.  Postangioplasty pseudoaneurysm treated with a vascular stent.

Authors:  C Blais; D Bonneau
Journal:  AJR Am J Roentgenol       Date:  1994-01       Impact factor: 3.959

2.  Percutaneous management of large-neck pseudoaneurysms with arterial stent placement and coil embolization.

Authors:  C J O'Brien; R N Rankin
Journal:  J Vasc Interv Radiol       Date:  1994 May-Jun       Impact factor: 3.464

3.  Endoluminal grafting for aneurysmal and occlusive disease in the superficial femoral artery: early experience.

Authors:  E B Diethrich; K Papazoglou
Journal:  J Endovasc Surg       Date:  1995-08

4.  Ulcerated plaques and focal aneurysms of iliac arteries: treatment with noncovered, self-expanding stents.

Authors:  D Vorwerk; R W Günther; G Wendt; K Schürmann
Journal:  AJR Am J Roentgenol       Date:  1994-06       Impact factor: 3.959

5.  Isolated iliac artery aneurysms.

Authors:  R A McCready; P C Pairolero; J C Gilmore; F J Kazmier; K J Cherry; L H Hollier
Journal:  Surgery       Date:  1983-05       Impact factor: 3.982

Review 6.  Natural history and management of iliac aneurysms.

Authors:  J W Richardson; L J Greenfield
Journal:  J Vasc Surg       Date:  1988-08       Impact factor: 4.268

7.  Transluminal placement of a prosthetic graft-stent device for treatment of subclavian artery aneurysm.

Authors:  J May; G White; R Waugh; W Yu; J Harris
Journal:  J Vasc Surg       Date:  1993-12       Impact factor: 4.268

8.  Percutaneous endoluminal placement of stent-grafts for the treatment of isolated iliac artery aneurysms.

Authors:  M K Razavi; M D Dake; C P Semba; U R Nyman; R P Liddell
Journal:  Radiology       Date:  1995-12       Impact factor: 11.105

9.  Solitary aneurysms of the iliac arterial system: an estimate of their frequency of occurrence.

Authors:  J Brunkwall; H Hauksson; H Bengtsson; D Bergqvist; R Takolander; S E Bergentz
Journal:  J Vasc Surg       Date:  1989-10       Impact factor: 4.268

10.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.

Authors:  J C Parodi; J C Palmaz; H D Barone
Journal:  Ann Vasc Surg       Date:  1991-11       Impact factor: 1.466

View more
  7 in total

1.  Repair of iliac artery aneurysms by endoluminal grafting: the systematic approach of one institution.

Authors:  M Nagarajan; P Chandrasekar; E Krishnan; S Muralidharan
Journal:  Tex Heart Inst J       Date:  2000

2.  Mathematical Model analysis of Wallstent and Aneurx: dynamic responses of bare-metal endoprosthesis compared with those of stent-graft.

Authors:  Suncica Canic; K Ravi-Chandar; Zvonimir Krajcer; Dragan Mirkovic; Serguei Lapin
Journal:  Tex Heart Inst J       Date:  2005

3.  Percutaneous common iliac artery aneurysm repair - a case report.

Authors:  Dipankar Mukherjee; Matthew Bowen
Journal:  Int J Angiol       Date:  2009

4.  A case of acute abdominal pain.

Authors:  Gailin Bronson Sebastian; Venketesh Radhakrishnan; Ashraf Safiya Manzil
Journal:  Heart Asia       Date:  2013-09-12

5.  More Than Just an Ulcer: A Case of HIV-Associated Iliac Aneurysms Presenting With a Leg Ulcer.

Authors:  Sherif Roman; Nader Mekheal; Shani Tal; Patrick Michael
Journal:  Cureus       Date:  2021-02-07

6.  Occlusion of experimentally created fusiform aneurysms with porous metallic stents.

Authors:  G Geremia; T Brack; L Brennecke; M Haklin; R Falter
Journal:  AJNR Am J Neuroradiol       Date:  2000-04       Impact factor: 3.825

7.  Comparison of Wallgraft and Wallstent for treatment of complex iliac artery stenosis and occlusion. Preliminary results of a prospective randomized study.

Authors:  Z Krajcer; G Sioco; T Reynolds
Journal:  Tex Heart Inst J       Date:  1997
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.